Auto-positive end-expiratory pressure and dynamic hyperinflation
- PMID: 8875002
- DOI: 10.1016/s0272-5231(05)70322-1
Auto-positive end-expiratory pressure and dynamic hyperinflation
Abstract
PEEP is indicated in patients with COPD only to unload the respiratory muscles from the auto-PEEP resulting from expiratory flow limitation. If auto-PEEP is not caused by flow limitation, application of PEEP will cause further hyperinflation, worsening respiratory mechanics, muscle activity, and hemodynamics. To assess the presence of expiratory flow limitation correctly, to measure auto-PEEP correctly, and to identify the maximal PEEP level to be used, measurements of flow and opening pressure must be obtained during a brief period of suspended respiratory muscle activity (obtained by sedation) with the patient's own breathing pattern reproduced accurately.
Similar articles
-
Hemodynamic responses to external counterbalancing of auto-positive end-expiratory pressure in mechanically ventilated patients with chronic obstructive pulmonary disease.Crit Care Med. 1994 Nov;22(11):1782-91. Crit Care Med. 1994. PMID: 7956282
-
Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients.Respir Care. 2005 Jan;50(1):110-23; discussion 123-4. Respir Care. 2005. PMID: 15636649 Review.
-
Auto-PEEP in respiratory failure.Minerva Anestesiol. 2012 Feb;78(2):201-21. Epub 2011 Nov 18. Minerva Anestesiol. 2012. PMID: 21971439 Review.
-
Airway occlusion pressure to titrate positive end-expiratory pressure in patients with dynamic hyperinflation.Anesthesiology. 2000 Jul;93(1):81-90. doi: 10.1097/00000542-200007000-00016. Anesthesiology. 2000. PMID: 10861149
-
Contribution of expiratory muscle pressure to dynamic intrinsic positive end-expiratory pressure: validation using the Campbell diagram.Am J Respir Crit Care Med. 2000 Nov;162(5):1633-40. doi: 10.1164/ajrccm.162.5.9903084. Am J Respir Crit Care Med. 2000. PMID: 11069788
Cited by
-
Dynamic hyperinflation and intrinsic positive end-expiratory pressure in ARDS patients.Crit Care. 2019 Nov 27;23(1):375. doi: 10.1186/s13054-019-2611-6. Crit Care. 2019. PMID: 31775830 Free PMC article.
-
Development of a bronchospasm device model.J Anesth. 2015 Feb;29(1):152-5. doi: 10.1007/s00540-014-1872-0. Epub 2014 Jul 4. J Anesth. 2015. PMID: 24993492
-
Review of ventilatory techniques to optimize mechanical ventilation in acute exacerbation of chronic obstructive pulmonary disease.Int J Chron Obstruct Pulmon Dis. 2007;2(4):441-52. Int J Chron Obstruct Pulmon Dis. 2007. PMID: 18268918 Free PMC article. Review.
-
As simple as possible, but not simpler.Intensive Care Med. 2000 Nov;26(11):1591-4. doi: 10.1007/s001340000672. Intensive Care Med. 2000. PMID: 11193263 Review. No abstract available.
-
Paradoxical responses to positive end-expiratory pressure in patients with airway obstruction during controlled ventilation.Crit Care Med. 2005 Jul;33(7):1519-28. doi: 10.1097/01.ccm.0000168044.98844.30. Crit Care Med. 2005. PMID: 16003057 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources