Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Sep;19(9):1363-9.
doi: 10.1111/j.1540-8159.1996.tb04216.x.

Risk of radiation induced skin injuries from arrhythmia ablation procedures

Affiliations

Risk of radiation induced skin injuries from arrhythmia ablation procedures

T H Park et al. Pacing Clin Electrophysiol. 1996 Sep.

Abstract

Catheter guided ablation of cardiac arrhythmias is an effective and safe procedure for the treatment of most supraventricular and selected ventricular tachycardias. Because catheter manipulation is fluoroscopically guided, there is risk of radiation induced injury, especially during prolonged procedures. The Food and Drug Administration has recently issued a bulletin warning of the risks of acute skin injury occurring during fluoroscopically guided procedures that result in an exposure level exceeding 2 Gray units (Gy). This study was performed as an investigation into the risk of radiation induced skin injury during arrhythmia ablation procedures. The amount of radiation exposure for 500 patients who underwent ablation was calculated based upon fluoroscopy times and the entrance dose of radiation (0.02 Gy/min). The mean radiation exposure was 0.93 +/- 0.62 Gy. Although 5.6% of patients (n = 28) received enough radiation exposure to reach the threshold dose (2 Gy) for early transient erythema, no clinical manifestations of acute radiation induced skin injury were observed. No patients achieved the threshold dose for irreversible skin injury. Patients undergoing AV node ablation or modification received significantly less radiation (0.39 +/- 0.40 Gy and 0.79 +/- 0.44 Gy, respectively) than patients undergoing other ablation procedures (0.94-1.45 Gy, P < 0.05). There was no association between the magnitude of radiation exposure and the presence of underlying heart disease. Patients undergoing ablation of accessory pathways were exposed to more radiation if there was a right-sided pathway (1.69 +/- 0.93 Gy) compared to other sites (0.87-1.24 Gy, P < 0.05). This study demonstrates that the risk of significant radiation induced skin injury during arrhythmia ablation procedures is low provided that precautions are taken to minimize radiation exposure.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources