Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996 Aug;77(2):165-71.
doi: 10.1093/bja/77.2.165.

Psychophysical and electrophysiological responses to experimental pain may be influenced by sedation: comparison of the effects of a hypnotic (propofol) and an analgesic (alfentanil)

Affiliations
Free article
Comparative Study

Psychophysical and electrophysiological responses to experimental pain may be influenced by sedation: comparison of the effects of a hypnotic (propofol) and an analgesic (alfentanil)

S Petersen-Felix et al. Br J Anaesth. 1996 Aug.
Free article

Abstract

Sedation may influence the responses of some experimental pain models used to test analgesic efficacy. In this study we compared the effects of a sedative (propofol) and analgesic (alfentanil) on: nociceptive reflex to single and repeated electrical stimulations; mechanical pressure pain; and evoked potentials elicited by nociceptive (electrical and laser) and non-nociceptive (acoustical) stimulation. We studied 12 healthy volunteers with two subanaesthetic concentrations of propofol and two analgesic concentrations of alfentanil. Both propofol and alfentanil increased the threshold for nociceptive reflex to single electrical stimulations, but only alfentanil increased the threshold for nociceptive reflex to repeated electrical stimulations. The pressure pain tolerance thresholds were increased significantly by alfentanil, whereas propofol significantly decreased the thresholds (hyperalgesia). Propofol and alfentanil induced similar reductions in the amplitudes of the evoked potentials elicited by nociceptive (electrical and laser) and non-nociceptive (acoustical) stimulation, whereas only alfentanil reduced the perceived pain to nociceptive stimulations. We have shown that sedation can influence both the psychophysical and electrophysiological responses of some experimental pain tests used to measure analgesic efficacy, and that propofol in subhypnotic doses, has no analgesic effect on painful electrical and heat stimulations, but has a hyperalgesic effect on mechanical pressure pain.

PubMed Disclaimer

Similar articles

Cited by

Publication types