Motif detection in quantum noise-limited electron micrographs by cross-correlation
- PMID: 888241
- DOI: 10.1016/s0304-3991(76)91385-1
Motif detection in quantum noise-limited electron micrographs by cross-correlation
Abstract
The use of cross-correlation to detect randomly positioned low-dose realizations of a motif in an image field is quantitatively evaluated. For both the bright- and dark-field cases, we derive theoretical expressions for the minimum dose allowing detection in terms of motif size, resolution, and contrast. Model computations on simulated low-dose images of a spherical virus particle give results that agree with our theoretical formulas and demonstrate the feasibility of this approach.
Similar articles
-
Three-dimensional reconstruction from electron micrographs of disordered specimens. II. Implementation and results.Ultramicroscopy. 1988;25(3):223-39. doi: 10.1016/0304-3991(88)90017-4. Ultramicroscopy. 1988. PMID: 3212838
-
Crystallization and preliminary X-ray study of a double-shelled spherical virus, rice dwarf virus.J Mol Biol. 1991 Jun 20;219(4):665-9. doi: 10.1016/0022-2836(91)90663-q. J Mol Biol. 1991. PMID: 2056533
-
Maximum entropy methods in dark field electron micrographs and elemental maps.Scanning Microsc Suppl. 1988;2:75-81. Scanning Microsc Suppl. 1988. PMID: 3244975
-
Special specimen preparation methods for image processing in transmission electron microscopy: a review.J Microsc. 1978 Aug;113(3):241-56. doi: 10.1111/j.1365-2818.1978.tb00103.x. J Microsc. 1978. PMID: 361958 Review.
-
Electron microscopy of integrins.Methods Enzymol. 2007;426:337-73. doi: 10.1016/S0076-6879(07)26015-X. Methods Enzymol. 2007. PMID: 17697891 Review.
Cited by
-
The translation elongation cycle-capturing multiple states by cryo-electron microscopy.Philos Trans R Soc Lond B Biol Sci. 2017 Mar 19;372(1716):20160180. doi: 10.1098/rstb.2016.0180. Philos Trans R Soc Lond B Biol Sci. 2017. PMID: 28138066 Free PMC article. Review.
-
Radiation damage in single-particle cryo-electron microscopy: effects of dose and dose rate.J Synchrotron Radiat. 2011 May;18(Pt 3):398-412. doi: 10.1107/S090904951100820X. Epub 2011 Apr 9. J Synchrotron Radiat. 2011. PMID: 21525648 Free PMC article.
-
How Cryo-EM Became so Hot.Cell. 2017 Nov 30;171(6):1229-1231. doi: 10.1016/j.cell.2017.11.016. Cell. 2017. PMID: 29195065 Free PMC article.
-
Characteristic views of E. coli and B. stearothermophilus 30S ribosomal subunits in the electron microscope.EMBO J. 1985 Sep;4(9):2389-95. doi: 10.1002/j.1460-2075.1985.tb03944.x. EMBO J. 1985. PMID: 3908096 Free PMC article.
-
Cryo electron microscopy to determine the structure of macromolecular complexes.Methods. 2016 Feb 15;95:78-85. doi: 10.1016/j.ymeth.2015.11.023. Epub 2015 Nov 27. Methods. 2016. PMID: 26638773 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Other Literature Sources