Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1996 Oct;18(5):604-9.
doi: 10.1097/00007691-199610000-00014.

A high-performance liquid chromatographic assay for the determination of amphotericin B serum concentrations after the administration of AmBisome, a liposomal amphotericin B formulation

Affiliations
Clinical Trial

A high-performance liquid chromatographic assay for the determination of amphotericin B serum concentrations after the administration of AmBisome, a liposomal amphotericin B formulation

A Alak et al. Ther Drug Monit. 1996 Oct.

Abstract

A sensitive and selective high-performance liquid chromatographic (HPLC) method has been developed for the determination of amphotericin B in human serum. After methanol deproteinization, amphotericin B and 3-nitrophenol (internal standard) are separated by reversed-phase chromatography and detected by ultraviolet absorbance. The analysis of human serum after the standard addition of amphotericin B (0.05-200.0 micrograms/mL) demonstrated excellent precision and accuracy over a five-day period. The HPLC assay uses two standard curve ranges. The high sensitivity curve range for low AmBisome dosage (1.0 mg/kg) is 0.05-20.0 micrograms/mL (curve 1), and the second curve range for the higher AmBisome dose regimens (2.5-5.0 mg/kg) is 0.5-200 micrograms/mL (curve 2). The intraday and interday coefficients of variations for standard curve 1 were 0.5-4.6% and 3.0-11.5%, respectively. The limit of quantitation was 0.05 microgram/mL. The intraday and interday coefficients of variation for standard curve 2 were 2.0-3.6 and 6.9-10.1, respectively. No interfering peak at the retention time for Amphotericin B and the internal standard were present in blank serums or serum samples spiked with fifteen potential co-administrated drugs with Amphotericin B treatment. The method was used to quantitate serum concentrations of amphotericin B in patients after the administration of AmBisome, a liposomal formulation of amphotericin B.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources