Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Sep;21(5):764-70.
doi: 10.1016/S0363-5023(96)80189-4.

Biaxial long-stemmed multipronged distal components for revision/bone deficit total-wrist arthroplasty

Affiliations

Biaxial long-stemmed multipronged distal components for revision/bone deficit total-wrist arthroplasty

T K Cobb et al. J Hand Surg Am. 1996 Sep.

Abstract

Revision total-wrist arthroplasty has a high incidence of complications. Loosening is a significant problem for the distal implant. Because of the high failure rate of single-pronged distal implants after revision total-wrist arthroplasty, a custom multipronged distal component (biaxial total-wrist implant) was designed for use in patients with deficient bone stock who undergo revision operation. Ten cases of total-wrist arthroplasty with a custom long-stemmed multipronged distal component are presented. The preoperative diagnosis was failed total-wrist arthroplasty in 9 cases. Mean time from previous total-wrist arthroplasty to revision procedure was 5.6 years. At follow-up evaluation (mean, 3.8 years; range, 3.0-4.8 years), 2 patients had undergone arthrodesis: 1 patient at an outside institution 1 year after surgery for periprosthetic fracture of the radius, and 1 patient at our institution for distal implant loosening. The 8 other patients had functional total-wrist arthroplasties. At follow-up evaluation, all patients reported they were satisfied. Six patients reported no pain and 2 reported mild pain. Mean range of motion at follow-up evaluation was within the previously defined limits that allow patients to function in activities of daily living: 78 degrees for supination, 77 degrees for pronation, 39 degrees for extension, 17 degrees for flexion, 12 degrees for radial deviation, and 18 degrees for ulnar deviation. Revision total-wrist arthroplasty with custom long-stemmed, multipronged distal components offers an alternative to those patients with deficient bone stock who refuse arthrodesis. Early results demonstrate greater longevity compared with single-pronged components for revision total-wrist arthroplasty.

PubMed Disclaimer

LinkOut - more resources