PET imaging using gamma camera systems: a review
- PMID: 8895903
- DOI: 10.1097/00006231-199609000-00006
PET imaging using gamma camera systems: a review
Abstract
Optimized positron emission tomographs have begun to demonstrate an ever widening range of clinical applications for positron labelled pharmaceuticals. This potential has led to a renewed interest in the use of the more widely available Anger gamma camera detectors for imaging the 511 keV photons from the positron decay process. Two forms of detection can be considered: either the detection of the 511 keV photons as single events or the detection of coincidence events from the opposed pair annihilation photons. The widespread availability of dual, opposed-pair, large field-of-view detectors has promoted the development of coincidence detection without collimation. With detector rotation, positron emission tomography (PET) can be performed. An alternative and lower cost option has been the universal development of ultra high-energy collimators to perform single photon emission tomography (SPET) with 511 keV photons. This review outlines the currently available performance characteristics of these two approaches and compares them with those from two- and three-dimensional PET optimized systems. The limitations on the development of these systems is discussed through the analysis of the principles underlying both single photon and coincidence detection. Preliminary clinical experience indicates that limitations in the performance characteristics of these systems has implications for their potential role, although applications in cardiology and oncology are being pursued.
Similar articles
-
PET imaging using gamma cameras.Comput Med Imaging Graph. 2001 Mar-Apr;25(2):87-96. doi: 10.1016/s0895-6111(00)00058-6. Comput Med Imaging Graph. 2001. PMID: 11137784 Review.
-
Three-gamma annihilation imaging in positron emission tomography.IEEE Trans Med Imaging. 2004 Apr;23(4):525-9. doi: 10.1109/TMI.2004.824150. IEEE Trans Med Imaging. 2004. PMID: 15084078
-
The role of hybrid cameras in oncology.Semin Nucl Med. 2000 Oct;30(4):268-80. doi: 10.1053/snuc.2000.9541. Semin Nucl Med. 2000. PMID: 11105928 Review.
-
Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.Phys Med Biol. 2007 Jul 7;52(13):3753-72. doi: 10.1088/0031-9155/52/13/007. Epub 2007 May 29. Phys Med Biol. 2007. PMID: 17664575 Free PMC article.
-
Experience with fully 3D PET and implications for future high-resolution 3D tomographs.Phys Med Biol. 1998 Apr;43(4):777-86. doi: 10.1088/0031-9155/43/4/007. Phys Med Biol. 1998. PMID: 9572503
Cited by
-
Brain fluorine-18 fluorodeoxyglucose imaging with dual-head coincidence gamma camera: comparison with dedicated ring-detector positron emission tomography.AJNR Am J Neuroradiol. 2000 Jan;21(1):99-104. AJNR Am J Neuroradiol. 2000. PMID: 10669232 Free PMC article. Clinical Trial.
-
[18F]FDG imaging of head and neck tumours: comparison of hybrid PET and morphological methods.Eur J Nucl Med Mol Imaging. 2003 Jul;30(7):995-1003. doi: 10.1007/s00259-003-1181-6. Epub 2003 May 9. Eur J Nucl Med Mol Imaging. 2003. PMID: 12739070 Clinical Trial.
-
Fluorine-18-deoxyglucose SPECT and coincidence imaging for myocardial viability: Clinical and technologic issues.J Nucl Cardiol. 2001 Jan-Feb;8(1):75-88. doi: 10.1067/mnc.2001.111409. J Nucl Cardiol. 2001. PMID: 11182712 Review. No abstract available.
-
A new PET system for small-animal imaging.IEEE Nucl Sci Symp Conf Rec (1997). 2004 Oct;6:3389-3392. doi: 10.1109/NSSMIC.2004.1466614. IEEE Nucl Sci Symp Conf Rec (1997). 2004. PMID: 26937167 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources