Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 1996 Mar;34(3):634-7.
doi: 10.1128/jcm.34.3.634-637.1996.

Multicenter evaluation of new double-antigen sandwich enzyme immunoassay for measurement of anti-human immunodeficiency virus type 1 and type 2 antibodies

Affiliations
Multicenter Study

Multicenter evaluation of new double-antigen sandwich enzyme immunoassay for measurement of anti-human immunodeficiency virus type 1 and type 2 antibodies

P Burgisser et al. J Clin Microbiol. 1996 Mar.

Abstract

A new enzyme immunoassay (EIA), the Cobas Core Anti-HIV-1/HIV-2 EIA DAGS (also referred to as Roche DAGS), for the detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 was evaluated in four centers. The assay is based on the double-antigen sandwich (DAGS) format, which enables the detection of all classes of antibodies. The antigens consist of recombinant proteins in their native conformation and of synthetic peptides. Of a total of 5,836 negative serum samples, including 95 samples likely to produce false reactivities, 6 were false positive, resulting in a specificity of 99.9%. None of 35 sera that were from noninfected individuals but contained p24-cross-reacting antibodies as revealed by Western blot (immunoblot) analysis were reactive by the Roche DAGS assay. In samples from individuals infected with HIV-1 group M (n = 499) and HIV-2 (n = 200), the sensitivity of the assay was 100%. Although containing antigens with sequences from subtype B only, the assay was also able to correctly identify with high optical density/cutoff ratios samples from subjects infected with HIV-1 subtype O (n = 10). In 17 of 19 seroconversion panels tested, the assay detected the presence of HIV-1 antibodies as early as another sandwich EIA. Eight of these panels were also analyzed by an indirect second-generation assay, which detected antibodies 2 to 10 days later than did the DAGS assay under evaluation. The excellent specificity and sensitivity of the new Cobas Core Anti-HIV-1/HIV-2 EIA DAGS are the result of the DAGS format as well as of the native, naturally folded form of the recombinant protein used as the gag antigen.

PubMed Disclaimer

References

    1. AIDS. 1988 Feb;2(1):11-5 - PubMed
    1. Clin Diagn Lab Immunol. 1995 Jul;2(4):458-61 - PubMed
    1. JAMA. 1989 Jul 7;262(1):64-9 - PubMed
    1. Blood. 1990 Aug 1;76(3):641-5 - PubMed
    1. J Clin Microbiol. 1992 Apr;30(4):801-5 - PubMed

Publication types

LinkOut - more resources