Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Nov;112(5):1268-74.
doi: 10.1016/S0022-5223(96)70140-X.

Port-access mitral valve replacement in dogs

Affiliations
Free article

Port-access mitral valve replacement in dogs

M F Pompili et al. J Thorac Cardiovasc Surg. 1996 Nov.
Free article

Abstract

Objective: The objective was to assess mitral valve replacement in a minimally invasive fashion by means of port-access technology.

Methods: Fifteen dogs, 28 +/- 3 kg (mean +/- standard deviation), were studied with the port-access mitral valve replacement system (Heartport, Inc., Redwood City, Calif.). Eleven dogs underwent acute studies and were sacrificed immediately after the procedure. Four dogs were allowed to recover and then were sacrificed 4 weeks after operation. Cardiopulmonary bypass was conducted by femoral cannulation with an endovascular balloon catheter for aortic occlusion, root venting, and antegrade delivery of cardioplegic solution. Catheters were inserted in the jugular vein for pulmonary artery venting and retrograde delivery of cardioplegic solution. Through the oval port, a prosthesis (St. Jude Medical, Inc., St. Paul, Minn., or CarboMedics, Inc., Austin, Texas) was inserted through the left atrial appendage and secured to the anulus with sutures. Deairing was performed.

Results: Cardiopulmonary bypass duration was 114 +/- 24 minutes and aortic crossclamp time was 68 +/- 14 minutes. All animals were weaned from cardiopulmonary bypass in sinus rhythm. Cardiac output and pulmonary artery occlusion pressure were unchanged (2.8 +/- 0.7 L/min and 7 +/- 3 mm Hg before operation vs 2.6 +/- 0.6 L/min and 9 +/- 4 mm Hg after operation). There was no mitral regurgitation according to left ventriculography in 13 of 15 dogs. In two dogs there was interference with prosthetic valve closure by residual native anterior leaflet tissue. Pathologic examination otherwise showed normal healing without perivalvular discontinuity. Microscopic studies showed no damage to the valve surfaces. Transthoracic echocardiography of the four dogs in the long-term study showed normal ventricular and prosthetic valve function 4 weeks after the operation.

Conclusion: Mitral valve replacement with a minimally invasive method has been demonstrated in dogs. A clinical trial is in progress.

PubMed Disclaimer

Publication types