Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996 Nov 15;78(10):1119-23.
doi: 10.1016/s0002-9149(96)90063-6.

Comparison of quantitation of left ventricular volume, ejection fraction, and cardiac output in patients with atrial fibrillation by cine magnetic resonance imaging versus invasive measurements

Affiliations
Comparative Study

Comparison of quantitation of left ventricular volume, ejection fraction, and cardiac output in patients with atrial fibrillation by cine magnetic resonance imaging versus invasive measurements

W G Hundley et al. Am J Cardiol. .

Abstract

Currently available invasive and noninvasive techniques for the determination of left ventricular end-diastolic and end-systolic volumes, ejection fraction, and cardiac output are more time-consuming and potentially less accurate in patients with atrial fibrillation (AF) than in those with sinus rhythm. Although magnetic resonance imaging (MRI) can rapidly and accurately measure these variables in patients with sinus rhythm, its ability to do so in subjects with AF is not known. To determine if left ventricular volumes, ejection fraction, and cardiac output can be measured accurately in patients with AF using MRI, 26 subjects (13 women and 13 men, aged 15 to 76 years) in sinus rhythm (n = 13) or AF (n = 13) underwent MRI followed immediately by invasive measurements of these indexes. For those in AF, MRI measurements of left ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, and cardiac output correlated well with catheterization measurements (r = 0.90, 0.90, 0.95, 0.85, and 0.90, respectively). In addition, the mean difference between MRI and catheterization measurements was similar in subjects with AF and in those with sinus rhythm. Compared with standard invasive measurements, MRI provides an accurate noninvasive determination of left ventricular volumes, ejection fraction, and cardiac output in patients with AF.

PubMed Disclaimer

Publication types

LinkOut - more resources