European multicentre evaluation of a commercial system for identification of methicillin-resistant Staphylococcus aureus
- PMID: 8922577
- DOI: 10.1007/BF01691964
European multicentre evaluation of a commercial system for identification of methicillin-resistant Staphylococcus aureus
Abstract
A commercial system for the rapid detection of methicillin-resistant Staphylococcus aureus, the BBL Crystal MRSA test (C-MRSA ID; Becton Dickinson, USA), was evaluated prospectively and compared with a polymerase chain reaction test for the presence of the mecA gene. Ten European centres tested a total of 676 isolates of Staphylococcus aureus from blood cultures. The system correctly identified 661 (97.8%) isolates within 4 h. All but three mecA gene-negative isolates (99.4% specificity) yielded a negative C-MRSA ID reaction, and 158 of 170 mecA gene-positive isolates were accurately detected (92.9% sensitivity). After repeated testing of discrepant results, sensitivity and specificity increased to 99% and 100%, respectively.
Comment in
-
Detection of methicillin-resistant Staphylococcus aureus using the BBL crystal MRSA kit.Eur J Clin Microbiol Infect Dis. 1997 Jun;16(6):481. doi: 10.1007/BF02471920. Eur J Clin Microbiol Infect Dis. 1997. PMID: 9248759 No abstract available.