Respiratory parameter estimation using forced oscillatory impedance data
- PMID: 893291
- DOI: 10.1152/jappl.1977.43.2.322
Respiratory parameter estimation using forced oscillatory impedance data
Abstract
The frequency dependency of the magnitude and phase angle of total respiratory impedance was measured in apneic dogs at functional residual capacity during forced oscillation by a special electronics unit. Regression analysis of these data yielded estimates of total respiratory resistance (RFO), inertance (IFO), and compliance (CFO). After correcting for the effects of the endotracheal tube, mean control values (+/-SE) of RFO, IFO, and CFO for the clinically normal dogs were 1.30+/-0.10 cmH2O-1-1-s, 0.0114+/-0.0022 cmH2O-1-1-s2, and 0.0306+/-0.0009 1-cm H2O-1, respectively. Estimates obtained with added resistance, a less dense gas, and abdominal weighting were consistent with predicted effects. In four dogs with mild respiratory symptoms, mean RFO was significantly elevated with no change in IFO or CFO. Independent measurements of resistance and compliance during tidal ventilation correlated well with RFO (r=0.87) and CFO (r=0.80), but RFO and CFO were, on the average, 71% of the tidal breathing values. Thus, the method provides precise estimates of RFO, IFO, and CFO, and allows detection of small changes in these parameters.
Similar articles
-
Forced oscillatory respiratory parameters following papain exposure in dogs.J Appl Physiol Respir Environ Exerc Physiol. 1979 Jan;46(1):61-6. doi: 10.1152/jappl.1979.46.1.61. J Appl Physiol Respir Environ Exerc Physiol. 1979. PMID: 457531
-
Forced oscillatory resistance and compliance parameters following pneumonectomy in beagle dogs.Respiration. 1981;41(1):17-24. doi: 10.1159/000194354. Respiration. 1981. PMID: 7244389
-
Respiratory resistance by end-inspiratory occlusion and forced oscillations in intubated patients.J Appl Physiol (1985). 1996 Apr;80(4):1105-11. doi: 10.1152/jappl.1996.80.4.1105. J Appl Physiol (1985). 1996. PMID: 8926233
-
Respiratory impedance and derived parameters in young children by forced random noise.J Appl Physiol Respir Environ Exerc Physiol. 1979 Jul;47(1):169-74. doi: 10.1152/jappl.1979.47.1.169. J Appl Physiol Respir Environ Exerc Physiol. 1979. PMID: 468656
-
Respiratory mechanics of Pekin ducks under four conditions: pressure breathing, anesthesia, paralysis or breathing CO2-enriched gas.Respir Physiol. 1982 Feb;47(2):177-91. doi: 10.1016/0034-5687(82)90110-4. Respir Physiol. 1982. PMID: 6803317
Cited by
-
Measurement of total respiratory impedance in dogs by the forced oscillation technique.Vet Res Commun. 1993;17(3):227-39. doi: 10.1007/BF01839171. Vet Res Commun. 1993. PMID: 8284900
-
Linear-lumped-parameter modeling of pulmonary impedance in monkeys.Ann Biomed Eng. 1986;14(5):401-15. doi: 10.1007/BF02367361. Ann Biomed Eng. 1986. PMID: 3789486
-
A comparison of endotracheal tube compensation techniques for the measurement of respiratory mechanical impedance at low frequencies.J Clin Monit Comput. 2022 Oct;36(5):1461-1477. doi: 10.1007/s10877-021-00788-9. Epub 2021 Dec 15. J Clin Monit Comput. 2022. PMID: 34910285 Free PMC article.
-
Characterizing respiratory mechanics with forced excitation techniques.Ann Biomed Eng. 1981;9(5-6):475-88. doi: 10.1007/BF02364765. Ann Biomed Eng. 1981. PMID: 6753663 Review. No abstract available.