Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1996 Dec;34(12):3016-22.
doi: 10.1128/jcm.34.12.3016-3022.1996.

Multicenter comparison of three commercial methods for quantification of human immunodeficiency virus type 1 RNA in plasma

Affiliations
Clinical Trial

Multicenter comparison of three commercial methods for quantification of human immunodeficiency virus type 1 RNA in plasma

R Schuurman et al. J Clin Microbiol. 1996 Dec.

Abstract

Three procedures for the quantification of human immunodeficiency virus type 1 (HIV-1) RNA from plasma were compared at three laboratories. The comparison involved the Quantiplex branched DNA assay (version 1.0) by Chiron Diagnostics, the NASBA-QT assay by Organon Teknika, and the Amplicor Monitor assay by Roche Molecular Systems. The laboratories performed each of the three assays with the same sets of reconstructed HIV-1-infected human plasma samples, cross-sectionally collected clinical plasma samples and longitudinally collected plasma samples from patients starting zidovudine therapy. Analysis of the reconstruction panel results for interlaboratory variation demonstrated that no laboratory differences in results were detected for any of the assays. A comparison of the reproducibilities of duplicate samples analyzed by batch and in separate assay runs demonstrated that the reproducibilities of the test results were similar within one assay and appeared to be independent of the HIV-1 concentration. The best reproducibility was obtained with the Quantiplex assay, but all three assays demonstrated equal reliability, which was independent of batched or unbatched analysis of replicate samples. Differences in the absolute concentrations calculated were observed for the assays, in particular in the analysis of reconstructed samples. In all assays, similar changes in plasma HIV-1 RNA concentrations were determined for longitudinally collected clinical samples.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Infect Dis. 1991 Apr;163(4):862-6 - PubMed
    1. J Clin Microbiol. 1996 Nov;34(11):2695-701 - PubMed
    1. J Infect Dis. 1992 Jun;165(6):1119-23 - PubMed
    1. Virology. 1992 Aug;189(2):695-714 - PubMed
    1. Science. 1993 Mar 19;259(5102):1749-54 - PubMed

LinkOut - more resources