Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996 Dec;34(12):3147-50.
doi: 10.1128/jcm.34.12.3147-3150.1996.

Multicenter evaluation of a fluorometric enzyme immunocapture assay to detect toxoplasma-specific immunoglobulin M in dried blood filter paper specimens from newborns

Affiliations
Comparative Study

Multicenter evaluation of a fluorometric enzyme immunocapture assay to detect toxoplasma-specific immunoglobulin M in dried blood filter paper specimens from newborns

R B Eaton et al. J Clin Microbiol. 1996 Dec.

Abstract

An easy-to-perform fluorometric enzyme immunocapture assay (FEIA) was developed by Labsystems, Helsinki, Finland, to detect toxoplasma-specific immunoglobulin M (IgM) in dried blood spots. Assay materials were distributed to two sites that have programs in place designed to identify infants born with congenital toxoplasma infection: the Statens Serum Institut, Copenhagen, Denmark, and the New England Regional Newborn Screening Program, Boston, Mass. Each site tested over 700 dried blood samples from healthy newborns to define a cutoff at the 99.5 percentile (5 enzyme immunounits for Copenhagen and 4 enzyme immunounits for Boston). Each site then applied its own cutoff of interpret results for dried blood spots prepared from either adults with serology suggestive of acute infection (Copenhagen) or infants determined to be congenitally infected on the basis of serological criteria (Boston). In Copenhagen, 35 of 38 adult samples were either positive to a small degree or borderline positive for IgA. These samples thus may not represent acute infection. In Boston, of 26 congenitally infected infants, 22 were positive by FEIA. The four infant specimens not positive by FEIA were either negative or borderline positive by the standard Boston assay. These results demonstrate that the IgM FEIA is a potential alternative to other filter paper assay for toxoplasma-specific IgM currently in use for newborns.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Scand J Infect Dis Suppl. 1992;84:43-5 - PubMed
    1. Anal Biochem. 1974 Jul;60(1):149-52 - PubMed
    1. N Engl J Med. 1994 Jun 30;330(26):1858-63 - PubMed
    1. J Immunol. 1983 Dec;131(6):2895-902 - PubMed
    1. J Immunoassay. 1991;12(1):29-46 - PubMed

LinkOut - more resources