Abstract
In this paper methods used to measure observer performance are reviewed, and a simple general model for finding and reporting target objects in gray-scale image backgrounds is presented. That model provides the basis for a combined measurement of detection and localization performance in various image-interpretation tasks, whether by human observers or by realized computer algorithms. The model assumes that (1) an observer's detection response and first choice of target location both depend on the "maximally suspicious" finding on an image, (2) a correct (first-choice) localization of the actual target occurs if and only if its location is selected as the most suspicious, and (3) a target's presence does not alter the degree of suspicion engendered by any other (normal) image findings. Formalization of these assumptions relates the ROC curve, which measures the ability to discriminate between images containing targets and images without targets, to the "Localization Response" (LROC) curve, which measures the conjoint ability to detect and correctly localize the actual targets in those images. A maximum-likelihood statistical procedure, developed for a two-parameter "binormal" version of this model, concurrently fits both the ROC and LROC curves from an observer's image ratings and target localizations for a set of image interpretations. The model's application is illustrated (and compared to standard ROC analysis) using sets of rating and localization data from radiologists asked to search chest films for pulmonary nodules. This model is then extended to multiple-report ("free-response") interpretations of multiple-target images, under the stringent requirement that an observer's detection capability and criterion for reporting possible targets both remain stationary across images and across the successive reports made on a given image. That extended model yields formulations and predictions for the so-called "Free-Response" (FROC) curve, and for a recently proposed "Alternative FROC" (AFROC) curve. Tests of that model's "stationarity" assumptions are illustrated using radiologists' free-search interpretations of chest films for pulmonary nodules, and they suggest that human observers may often violate those assumptions when making multiple-report interpretations of images.
Comment in
-
Operating characteristics predicted by models for diagnostic tasks involving lesion localization.Med Phys. 2008 Feb;35(2):435-45. doi: 10.1118/1.2820902. Med Phys. 2008. PMID: 18383663 Free PMC article.
Similar articles
-
Evaluating image reconstruction methods for tumor detection in 3-dimensional whole-body PET oncology imaging.J Nucl Med. 2003 Feb;44(2):276-90. J Nucl Med. 2003. PMID: 12571221
-
Maximum likelihood fitting of FROC curves under an initial-detection-and-candidate-analysis model.Med Phys. 2002 Dec;29(12):2861-70. doi: 10.1118/1.1524631. Med Phys. 2002. PMID: 12512721
-
Improved detection of subtle lung nodules by use of chest radiographs with bone suppression imaging: receiver operating characteristic analysis with and without localization.AJR Am J Roentgenol. 2011 May;196(5):W535-41. doi: 10.2214/AJR.10.4816. AJR Am J Roentgenol. 2011. PMID: 21512042
-
Visual perception studies and observer models in medical imaging.Semin Nucl Med. 2011 Nov;41(6):419-36. doi: 10.1053/j.semnuclmed.2011.06.005. Semin Nucl Med. 2011. PMID: 21978445 Review.
-
New developments in observer performance methodology in medical imaging.Semin Nucl Med. 2011 Nov;41(6):401-18. doi: 10.1053/j.semnuclmed.2011.07.001. Semin Nucl Med. 2011. PMID: 21978444 Free PMC article. Review.
Cited by
-
Subject-centered free-response ROC (FROC) analysis.Med Phys. 2013 May;40(5):051706. doi: 10.1118/1.4799843. Med Phys. 2013. PMID: 23635254 Free PMC article.
-
Approximating the Ideal Observer for Joint Signal Detection and Localization Tasks by use of Supervised Learning Methods.IEEE Trans Med Imaging. 2020 Dec;39(12):3992-4000. doi: 10.1109/TMI.2020.3009022. Epub 2020 Nov 30. IEEE Trans Med Imaging. 2020. PMID: 32746143 Free PMC article.
-
Joint reconstruction of Ictal/inter-ictal SPECT data for improved epileptic foci localization.Med Phys. 2017 Apr;44(4):1437-1444. doi: 10.1002/mp.12167. Med Phys. 2017. PMID: 28211105 Free PMC article.
-
Validation and statistical power comparison of methods for analyzing free-response observer performance studies.Acad Radiol. 2008 Dec;15(12):1554-66. doi: 10.1016/j.acra.2008.07.018. Acad Radiol. 2008. PMID: 19000872 Free PMC article.
-
Counterpoint to "Performance assessment of diagnostic systems under the FROC paradigm" by Gur and Rockette.Acad Radiol. 2009 Apr;16(4):507-10. doi: 10.1016/j.acra.2008.12.011. Acad Radiol. 2009. PMID: 19268864 Free PMC article. No abstract available.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources