. 1996 Nov;118(4):473-81.
doi: 10.1115/1.2796033.

Constitutive laws for biomechanical modeling of refractive surgery

Affiliations

Constitutive laws for biomechanical modeling of refractive surgery

M R Bryant et al. J Biomech Eng. 1996 Nov.

Abstract

Membrane inflation tests were performed on fresh, intact human corneas using a fiber optic displacement probe to measure the apical displacements. Finite element models of each test were used to identify the material properties for four different constitutive laws commonly used to model corneal refractive surgery. Finite element models of radial keratotomy using the different best-fit constitutive laws were then compared. The results suggest that the nonlinearity in the response of the cornea is material rather than geometric, and that material nonlinearity is important for modeling refractive surgery. It was also found that linear transverse isotropy is incapable of representing the anisotropy that has been experimentally measured by others, and that a hyperelastic law is not suitable for modeling the stiffening response of the cornea.

PubMed Disclaimer

Publication types

LinkOut - more resources