Comparative Study
. 1996 Dec;50(4):293-302.
doi: 10.1002/(SICI)1096-9071(199612)50:4<293::AID-JMV3>3.0.CO;2-3.

Comparative evaluation of three assays for the quantitation of human immunodeficiency virus type 1 RNA in plasma

Affiliations
Comparative Study

Comparative evaluation of three assays for the quantitation of human immunodeficiency virus type 1 RNA in plasma

J Coste et al. J Med Virol. 1996 Dec.

Abstract

Reverse transcriptase-coupled polymerase chain reaction (Amplicor HIV-1 Monitor), the branched DNA (bDNA) method (Quantiplex HIV-1 RNA) and the nucleic acid sequence-based assay (NASBA HIV-1 RNA QT) were comparatively evaluated for the quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in plasma. Among 60 plasma specimens from HIV-1 infected patients, HIV-1 RNA was detected in 56 by Amplicor (sensitivity, 93.3%), in 41 by bDNA (sensitivity, 68.3%), and in 60 by NASBA (sensitivity, 100%). HIV-1 RNA was not detected by any of these methods in 34/34 plasma specimens from HIV-1-seronegative blood donors (specificity, 100%). The HIV-1 RNA levels as determined by the different methods were correlated significantly. The frequency of concordant results (log difference < 0.50) was 80.4% between Amplicor and NASBA, 77.5% between Amplicor and bDNA, and 58.6% between bDNA and NASBA. After initiation of antiviral therapy, HIV-1 RNA level variations observed with the three methods were similar. HIV-1 RNA levels were inversely correlated with the CD4+ T cell counts, whereas no correlation was found with HIV-1 p24-antigen levels. When the methods were evaluated for reproducibility, coefficients of variation ranged from 11% to 40% for Amplicor, from 6% to 35% for bDNA, and from 13% to 62% for NASBA. Quantitation of HIV-1 RNA in culture supernatants from HIV-1 subtype A to H strains showed that bDNA can be used to quantitate RNA from all HIV-1 subtypes, whereas Amplicor failed to detect RNA from subtype A strains and NASBA subtype G strains.

PubMed Disclaimer