Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Dec;62(6):1617-21.
doi: 10.1016/s0003-4975(96)00612-1.

Intratracheal surfactant administration preserves airway compliance during lung reperfusion

Affiliations

Intratracheal surfactant administration preserves airway compliance during lung reperfusion

S A Buchanan et al. Ann Thorac Surg. 1996 Dec.

Abstract

Background: Decreased airway compliance after lung transplantation has been observed with severe ischemia-reperfusion injury. Further, it has been shown that the surfactant system is impaired after lung preservation and reperfusion. We hypothesized that surfactant replacement after allograft storage could preserve airway compliance during reperfusion.

Methods: Rabbit lungs were harvested after flush with 50 mL/kg of cold saline solution. Immediate control lungs were studied with an isolated ventilation/perfusion apparatus using venous rabbit blood recirculated at 40 mL/min, room-air ventilation at 20 breaths/min, and constant airway pressure (n = 8). Twenty-four-hour control lungs were preserved at 4 degrees C for 24 hours and then similarly studied (n = 7). Surfactant lungs underwent similar harvest and preservation for 24 hours, but received 1.5 mL/kg of intratracheal surfactant 5 minutes before reperfusion (n = 10). Airway pressure and flow were recorded continuously during 30 minutes of reperfusion. Tidal volume and airway compliance were calculated at 30 minutes.

Results: Tidal volume was 33.67 +/- 0.57, 15.75 +/- 5.72, and 29.83 +/- 1.07 mL in the immediate control, 24-hour control, and surfactant groups, respectively (p = 0.004, surfactant versus 24-hour control). Airway compliance was 1.94 +/- 0.27, 0.70 +/- 0.09, and 1.46 +/- 0.10 mL/mm Hg in the immediate control, 24-hour control, and surfactant groups, respectively (p = 0.002, surfactant versus 24-hour control).

Conclusions: We conclude that surfactant administration before reperfusion after 24 hours of cold storage preserves tidal volume and airway compliance in the isolated ventilated/perfused rabbit model of lung reperfusion injury.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources