Meta-Analysis
. 1996 Dec;24(12):2053-8.
doi: 10.1097/00003246-199612000-00020.

Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature

Affiliations
Meta-Analysis

Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature

A G Randolph et al. Crit Care Med. 1996 Dec.

Abstract

Objective: To evaluate the effect of real-time ultrasound guidance using a regular or Doppler ultrasound technique for placement of central venous catheters.

Data sources: We searched for published and unpublished research using MEDLINE, citation review of relevant primary and review articles, conference abstracts, personal files, and contact with expert informants.

Study selection: From a pool of 208 randomized, controlled trials of venous and arterial catheter management, eight published randomized, controlled trials were identified.

Data extraction: In duplicate, independently, we abstracted data on the population, intervention, outcome, and methodologic quality.

Data synthesis: Ultrasound guidance significantly decreases internal jugular and subclavian catheter placement failure (relative risk 0.32; 95% confidence interval 0.18 to 0.55), decreases complications during catheter placement (relative risk 0.22; 95% confidence interval 0.10 to 0.45), and decreases the need for multiple catheter placement attempts (relative risk 0.60; 95% confidence interval 0.45 to 0.79) when compared with the standard landmark placement technique.

Conclusions: When used for vessel location and catheter placement real-time, ultrasound guidance or Doppler ultrasound guidance improves success rates and decreases the complications associated with internal jugular and subclavian venous catheter placement.

PubMed Disclaimer

Comment in

  • ACP J Club. 1997 May-Jun;126(3):75