Comparison of plasma virus loads among individuals infected with hepatitis C virus (HCV) genotypes 1, 2, and 3 by quantiplex HCV RNA assay versions 1 and 2, Roche Monitor assay, and an in-house limiting dilution method
- PMID: 8968905
- PMCID: PMC229536
- DOI: 10.1128/jcm.35.1.187-192.1997
Comparison of plasma virus loads among individuals infected with hepatitis C virus (HCV) genotypes 1, 2, and 3 by quantiplex HCV RNA assay versions 1 and 2, Roche Monitor assay, and an in-house limiting dilution method
Abstract
The accuracy of different methods for the quantitation of hepatitis C virus in plasma was measured with samples from individuals infected with different genotypes and by using RNA transcripts of predetermined concentrations. Highly reproducible results were observed upon repeat testing of samples by both the original version of the Chiron branched-DNA (bDNA) assay (Quantiplex RNA assay; bDNA-1) and the currently available version (Quantiplex HCV RNA 2.0 assay; bDNA-2). A greater variability was observed in the Roche Monitor assay (correlation coefficient of 0.537, compared with 0.942 and 0.964 for the bDNA-1 and bDNA-2 assays, respectively). Significant differences in the efficiency of detection of genotypes 1, 2, and 3 were observed for the bDNA-1 and Roche Monitor assays, whereas the bDNA-2 assay and nested PCR at limiting dilution were able to quantify genotypes with equal sensitivity. By quantifying RNA transcripts of different genotypes, the sensitivities of the Roche Monitor assay for sequences of the type 2 and type 3 transcripts were estimated to be 11 and 8% of those achieved for genotype 1. When correction factors based upon these results and those from quantitation of circulating viral RNA sequences in samples from blood donors were used, the genotype-specific differences in virus load in samples from blood donors were no longer observed, consistent with previous studies with corrected values from the bDNA-1 assay. These results suggest that many of the previous studies evaluating the effect of genotype and virus load on the response to interferon using methods such as the Roche Monitor assay and other competitive PCR methods require reinterpretation. Differences in efficiency of quantitation should be taken into account in future investigations of the relationship between genotype and virus load.
Similar articles
-
Genotype dependence of hepatitis C virus load measurement in commercially available quantitative assays.J Clin Microbiol. 1999 Aug;37(8):2525-32. doi: 10.1128/JCM.37.8.2525-2532.1999. J Clin Microbiol. 1999. PMID: 10405395 Free PMC article.
-
Multilaboratory comparison of hepatitis C virus viral load assays.J Clin Microbiol. 2006 May;44(5):1726-32. doi: 10.1128/JCM.44.5.1726-1732.2006. J Clin Microbiol. 2006. PMID: 16672399 Free PMC article.
-
Comparative evaluation of hepatitis C virus RNA quantitation by branched DNA, NASBA, and monitor assays.Hepatology. 1999 Feb;29(2):528-35. doi: 10.1002/hep.510290237. Hepatology. 1999. PMID: 9918931
-
Comparative evaluation of the VERSANT HCV RNA 3.0, QUANTIPLEX HCV RNA 2.0, and COBAS AMPLICOR HCV MONITOR version 2.0 Assays for quantification of hepatitis C virus RNA in serum.J Clin Microbiol. 2002 Feb;40(2):495-500. doi: 10.1128/JCM.40.2.495-500.2002. J Clin Microbiol. 2002. PMID: 11825962 Free PMC article.
-
Comparison of quantitative HCV RNA assays in chronic hepatitis C.Am J Clin Pathol. 1997 Mar;107(3):362-7. doi: 10.1093/ajcp/107.3.362. Am J Clin Pathol. 1997. PMID: 9052389
Cited by
-
Frequent recovery and broad genotype 2 diversity characterize hepatitis C virus infection in Ghana, West Africa.J Virol. 2003 Jul;77(14):7914-23. doi: 10.1128/jvi.77.14.7914-7923.2003. J Virol. 2003. PMID: 12829831 Free PMC article.
-
HCV genotypes in patients with chronic hepatitis C in Croatia.Infection. 1998 May-Jun;26(3):173-7. doi: 10.1007/BF02771846. Infection. 1998. PMID: 9646111
-
Analytical variables influencing the HCV RNA determination by TaqMan real-time PCR in routine clinical laboratory practice.Mol Biol Rep. 2012 Jul;39(7):7421-7. doi: 10.1007/s11033-012-1574-3. Epub 2012 Feb 12. Mol Biol Rep. 2012. PMID: 22327777
-
Linkage of Crohn's disease to the major histocompatibility complex region is detected by multiple non-parametric analyses.Gut. 1999 Apr;44(4):519-26. doi: 10.1136/gut.44.4.519. Gut. 1999. PMID: 10075959 Free PMC article.
-
Current molecular methods for the detection of hepatitis C virus in high risk group population: A systematic review.World J Virol. 2015 Feb 12;4(1):25-32. doi: 10.5501/wjv.v4.i1.25. World J Virol. 2015. PMID: 25674515 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical