The diagnostic accuracy and complications of closed lung biopsies
- PMID: 897154
- DOI: 10.1148/125.1.11
The diagnostic accuracy and complications of closed lung biopsies
Abstract
The diagnostic yields and complication rates of closed lung biopsies were determined by responses to a questionnaire. Of 5,255 procedures reported, 30% were aspiration biopsies (AB), 7% tissue core biopsies (CB), 2% trephine biopsies (TR), 37% bronchial brush biopsies (BB), and 23% transbronchial biopsies (TB). Of these biopsies, 70% were done for suspected neoplasms. The diagnostic accuracy rates were: AB=82%, CB=84%, TR=86%, BB=61%, and TB=56%. Mortality rates were: AB=0.1%, CB=0.3%, TR=2.9%, BB=0.0%, and TB=0.3%. Transthoracic needle biopsies (AB, CB) had the highest overall diagnostic accuracy, with an associated low mortality and moderate morbidity.
Similar articles
-
Lung biopsy: methods, value, complications, timing, and indications.Pathol Res Pract. 1979 Apr;164(1):95-103. doi: 10.1016/S0344-0338(79)80097-7. Pathol Res Pract. 1979. PMID: 461224
-
Comparison of endobronchial needle aspiration with forceps and brush biopsies in the diagnosis of endobronchial lung cancer.Monaldi Arch Chest Dis. 1997 Feb;52(1):13-7. Monaldi Arch Chest Dis. 1997. PMID: 9151514
-
Trephine air drill, bronchial brush, and fiberoptic transbronchial lung biopsies in immunosuppressed patients.Am Rev Respir Dis. 1977 Feb;115(2):213-20. doi: 10.1164/arrd.1977.115.2.213. Am Rev Respir Dis. 1977. PMID: 842935
-
[Bronchoscopic diagnosis of peripheral pulmonary foci].Dtsch Med Wochenschr. 2006 Oct 6;131(40):2229-33. doi: 10.1055/s-2006-951358. Dtsch Med Wochenschr. 2006. PMID: 17021993 Review. German.
-
Transthoracic needle aspiration.Clin Chest Med. 1992 Mar;13(1):11-6. Clin Chest Med. 1992. PMID: 1582142 Review.
Cited by
-
Bronchoscopic evaluation of peripheral lung tumours.Thorax. 1988 Nov;43(11):887-9. doi: 10.1136/thx.43.11.887. Thorax. 1988. PMID: 3222759 Free PMC article.
-
Drill biopsy in the diagnosis of lung lesions.Thorax. 1987 Nov;42(11):858-62. doi: 10.1136/thx.42.11.858. Thorax. 1987. PMID: 3424267 Free PMC article.
-
Percutaneous lung biopsy: experiences during the first 54 biopsies.Cardiovasc Intervent Radiol. 1982;5(2):61-3. doi: 10.1007/BF02552078. Cardiovasc Intervent Radiol. 1982. PMID: 7105076
-
Prevention of pneumothorax in needle lung biopsy by breathing 100% oxygen.Thorax. 1980 Jan;35(1):37-41. doi: 10.1136/thx.35.1.37. Thorax. 1980. PMID: 7361283 Free PMC article.
-
Six years' experience with perthoracic core needle biopsy in pulmonary lesions.Thorax. 1989 Mar;44(3):177-83. doi: 10.1136/thx.44.3.177. Thorax. 1989. PMID: 2705147 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources