Comparison of self-reporting of deficiencies in airway management with video analyses of actual performance. LOTAS Group. Level One Trauma Anesthesia Simulation
- PMID: 8976625
- DOI: 10.1518/001872096778827297
Comparison of self-reporting of deficiencies in airway management with video analyses of actual performance. LOTAS Group. Level One Trauma Anesthesia Simulation
Abstract
We compared the performance deficiencies of airway management captured by three types of self-reports with those identified through video analysis. The three types of self-reports were the anesthesia record (a patient record constructed during the course of treatment), the anesthesia quality assurance (AQA) report (a retrospective report as a part of the trauma center's quality assurance process), and a posttrauma treatment questionnaire (PTQ), which was completed immediately after the case for the purposes of this research. Video analysis of 48 patient encounters identified 28 performance deficiencies related to airway management in 11 cases (23%). The performance deficiencies took the form of task omissions or practices that lessened the margin of patient safety. In comparison, AQA reports identified none of these performance deficiencies, the anesthesia records identified 2 (of 28), and the PTQs suggested contributory factors and corrective measures for 5 deficiencies. Furthermore, video analysis provided information about the context of and factors contributing to the identified performance deficiencies, such as failures in adherence to standard operating procedures and in communications.
Similar articles
-
Task complexity in emergency medical care and its implications for team coordination. LOTAS Group. Level One Trauma Anesthesia Simulation.Hum Factors. 1996 Dec;38(4):636-45. doi: 10.1518/001872096778827206. Hum Factors. 1996. PMID: 8976626
-
Video as a tool for improving tracheal intubation tasks for emergency medical and trauma care.Ann Emerg Med. 2007 Oct;50(4):436-42, 442.e1. doi: 10.1016/j.annemergmed.2007.06.487. Ann Emerg Med. 2007. PMID: 17881317
-
An audio-video system for automated data acquisition in the clinical environment. LOTAS Group.J Clin Monit. 1995 Sep;11(5):335-41. doi: 10.1007/BF01616993. J Clin Monit. 1995. PMID: 7595691
-
Simulation and quality improvement in anesthesiology.Anesthesiol Clin. 2011 Mar;29(1):13-28. doi: 10.1016/j.anclin.2010.11.010. Epub 2010 Dec 16. Anesthesiol Clin. 2011. PMID: 21295750 Review.
-
The Genesis of a Trauma Performance Improvement Plan.J Trauma Nurs. 2015 Nov-Dec;22(6):315-20. doi: 10.1097/JTN.0000000000000166. J Trauma Nurs. 2015. PMID: 26574945 Review.
Cited by
-
A systems approach to surgical safety.Surg Endosc. 2002 Jun;16(6):1005-14; discussion 1015. doi: 10.1007/s00464-002-8509-3. Epub 2002 May 14. Surg Endosc. 2002. PMID: 12000985 No abstract available.
-
A quantitative study of disruption in the operating room during laparoscopic antireflux surgery.Surg Endosc. 2008 Oct;22(10):2171-7. doi: 10.1007/s00464-008-0017-7. Epub 2008 Jul 12. Surg Endosc. 2008. PMID: 18622567
-
[Personnel and structural requirements for the shock trauma room management of multiple trauma. A systematic review of the literature].Unfallchirurg. 2004 Oct;107(10):851-61. doi: 10.1007/s00113-004-0813-z. Unfallchirurg. 2004. PMID: 15459805 German.
-
Problems for clinical judgement: 3. Thinking clearly in an emergency.CMAJ. 2001 Apr 17;164(8):1170-5. CMAJ. 2001. PMID: 11338805 Free PMC article. Review.
-
Video capture of clinical care to enhance patient safety.Qual Saf Health Care. 2004 Apr;13(2):136-44. doi: 10.1136/qhc.13.2.136. Qual Saf Health Care. 2004. PMID: 15069222 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources