Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Dec;37(13):2771-4.

Cone-specific measures of human color vision

Affiliations
  • PMID: 8977494

Cone-specific measures of human color vision

J Rabin. Invest Ophthalmol Vis Sci. 1996 Dec.

Abstract

Purpose: To describe a new test of color vision (cone-specific contrast sensitivity) and to evaluate its sensitivity in comparison to standard clinical tests.

Methods: Cone-specific colored letter charts were generated by computer and displayed on a color monitor. Each chart consists of colored letters that are most visible at the top but that gradually fade into a gray background. Cone contrast varies systematically on each chart so that letters are visible to only one cone type (L, M, or S cone). Cone-specific letter contrast sensitivity was measured in 30 color normals and 13 subjects with hereditary color deficiency. Values were compared to standard measures of color vision.

Results: In color normals, mean log contrast sensitivity was approximately the same on L-cone (1.84 +/- 0.08 log contrast sensitivity) and M-cone (1.87 +/- 0.08) tests but was reduced on the S-cone test (0.89 +/- 0.15) because of the fewer number of S-cones in the human retina. Subjects with red color deficiency showed significantly reduced contrast sensitivity on the L-cone test but normal performance on M- and S-cone tests. Subjects with green color deficiency showed decreased contrast sensitivity limited to the M-cone test. When standardized relative to variability, cone contrast sensitivity identified color deficiency unequivocally in all subjects, whereas FM 100 hue error scores detected 9 of 13 subjects with color deficiency.

Conclusions: Cone-specific contrast sensitivity provides a quantitative measure of normal color vision and indicates both type and severity of color deficiency. It is useful for diagnosing hereditary color deficiency and for monitoring early color vision loss in ocular and systemic disease.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms