[Application of ion-selective electrodes for determining ion concentration in blood of irradiated rabbits]
- PMID: 898310
[Application of ion-selective electrodes for determining ion concentration in blood of irradiated rabbits]
Abstract
Concentration of potassium and sodium ions as well as chlorides in rabbit blood serum was determined by applying the direct potentiometric method using the ion-selective electrodes. The techniques on calibration of the applied ion-selective electrodes are described and comparative data are presented of determining the concentration of potassium and sodium by the potentiometric method and that of flame photometry and of chlorides by the potentiometric and chemical methods. By high-specific ion-selective electrodes (glass for Na+, membrane one for Cl- and valinemycinic for R+) the character of ionic disturbances is established in the blood serum of rabbits irradiated with a dose of 2000 R. The concentration of potassium ions decreases 15-18 degrees min after irradiation. The concentration of sodium ions and chlorides is not changed noticeably. The concentration of calcium determined by the method of flame photometry decreases after irradiation within a range of 30 min-72h. The found changes may be explained by the damaging effect of radiation on the structure and function of the cell membranes.
Similar articles
-
[Determination of electrolytes in serum and plasma].Wien Klin Wochenschr Suppl. 1992;192:37-41. Wien Klin Wochenschr Suppl. 1992. PMID: 1502823 Review. German.
-
[Potentiometric method of determining plasma and serum concentrations of potassium and sodium using ion-selective electrodes].Gig Sanit. 1984 Aug;(8):68-9. Gig Sanit. 1984. PMID: 6489785 Russian. No abstract available.
-
[Determination of blood sodium, potassium and chloride by means of ion-selective electrodes].Wien Med Wochenschr. 1978 Mar 15;128(5):125-9. Wien Med Wochenschr. 1978. PMID: 645078 German. No abstract available.
-
International Federation of Clinical Chemistry (IFCC). Recommendation on mean molar activity coefficients and single ion activity coefficients of solutions for calibration of ion-selective electrodes for sodium, potassium and calcium determination.Eur J Clin Chem Clin Biochem. 1997 Apr;35(4):345-9. Eur J Clin Chem Clin Biochem. 1997. PMID: 9166979
-
A comparison of the measurement of sodium and potassium by flame photometry and ion-selective electrode.Ann Clin Biochem. 1985 Jul;22 ( Pt 4):343-50. doi: 10.1177/000456328502200402. Ann Clin Biochem. 1985. PMID: 3898973 Review.