Antinuclear antibody determination in a routine laboratory
- PMID: 8984936
- PMCID: PMC1010287
- DOI: 10.1136/ard.55.10.723
Antinuclear antibody determination in a routine laboratory
Abstract
Pitfalls in the method for demonstrating antinuclear antibodies (ANA) by the indirect immunofluorescence technique are described and the use of international standard preparations outlined. Determination of the optimal border dilution dividing positive from negative results is discussed. Each laboratory is a unique setting; it must define its own method, which should rarely be changed. One should not rely on copying methods from other laboratories or commercial firms, but the reproducibility of the nuclear substrate, the conjugate, and other variables should be controlled daily by the use of a control serum which has been related to the WHO standard preparation for ANA of the homogeneous type. Since many sera contain mixtures of different ANA, the results of routine tests are best expressed in titres or expressions of the intensity of fluorescence. The ANA test using the immunofluorescence technique should be used as a screening method for other tests allowing a more defined interpretation of the ANA. Each laboratory should individually determine the border between positive and negative results. Therefore about 200 sera from local healthy controls equally distributed over sex and age, and 100 sera from local patients with definite SLE should be tested. Since the local clinicians should become acquainted with this border it should rarely be changed. Finally each laboratory should participate regularly in national and international quality control rounds, where sera known to be difficult to interpret are tested. The judgment of the organisers of these rounds should stimulate improvements in the participating laboratories.
Similar articles
-
Antinuclear antibodies by indirect immunofluorescence : optimum screening dilution for diagnosis of systemic lupus erythematosus.Indian J Med Res. 2007 Jul;126(1):34-8. Indian J Med Res. 2007. PMID: 17890821
-
Automated antinuclear immunofluorescence antibody analysis is a reliable approach in routine clinical laboratories.Clin Chem Lab Med. 2017 Oct 26;55(12):1922-1930. doi: 10.1515/cclm-2017-0050. Clin Chem Lab Med. 2017. PMID: 28467309
-
A fully automated IIF system for the detection of antinuclear antibodies and antineutrophil cytoplasmic antibodies.Immunol Res. 2015 Feb;61(1-2):135-40. doi: 10.1007/s12026-014-8588-y. Immunol Res. 2015. PMID: 25403695
-
Automated antinuclear immunofluorescence antibody screening: a comparative study of six computer-aided diagnostic systems.Autoimmun Rev. 2014 Mar;13(3):292-8. doi: 10.1016/j.autrev.2013.10.015. Epub 2013 Nov 9. Autoimmun Rev. 2014. PMID: 24220268 Review.
-
[Modern look at the problems of investigation of antinuclear antibodies in systemic lupus erythematosus (literature review).].Klin Lab Diagn. 2018;63(6):340-348. doi: 10.18821/0869-2084-2018-63-6-340-348. Klin Lab Diagn. 2018. PMID: 30702224 Review. Russian.
Cited by
-
Antinuclear antibodies and their detection methods in diagnosis of connective tissue diseases: a journey revisited.Diagn Pathol. 2009 Jan 2;4:1. doi: 10.1186/1746-1596-4-1. Diagn Pathol. 2009. PMID: 19121207 Free PMC article.
-
The use and abuse of commercial kits used to detect autoantibodies.Arthritis Res Ther. 2003;5(4):192-201. doi: 10.1186/ar782. Epub 2003 Jun 9. Arthritis Res Ther. 2003. PMID: 12823850 Free PMC article. Review.
-
Autoantibodies and their Judicious Use in Pediatric Rheumatology Practice.Indian J Pediatr. 2016 Jan;83(1):53-62. doi: 10.1007/s12098-015-1936-7. Epub 2015 Dec 3. Indian J Pediatr. 2016. PMID: 26631069 Review.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources