Cross-sectional sample preparation by focused ion beam: a review of ion-sample interaction
- PMID: 8987026
- DOI: 10.1002/(SICI)1097-0029(19961101)35:4<320::AID-JEMT3>3.0.CO;2-Q
Cross-sectional sample preparation by focused ion beam: a review of ion-sample interaction
Abstract
A focused ion beam (FIB) was applied for cross-sectional sample preparation with both transmission electron microscopes (TEM) and scanning electron microscopes (SEM). The FIB sample preparation has the advantage of high positioning accuracy for cross sections. On the other hand, a broad ion beam (BIB) has been conventionally used for thinning TEM samples. Although both FIB and BIB use energetic ion beams, they are essentially different from each other in many aspects such as beam size, beam current density, incident angle of the beam with respect to cross sections, and beam scanning (i.e., dynamic or static beam). In this study, FIB cross-sectioning is compared with BIB thinning. We review inherent characteristics such as positioning accuracy and uniformity of cross section, radiation damage, and beam heating. Discussion is held from a view-point of ion beam and sample interaction.
Similar articles
-
The correlation between ion beam/material interactions and practical FIB specimen preparation.Microsc Microanal. 2003 Jun;9(3):216-36. doi: 10.1017/S1431927603030034. Microsc Microanal. 2003. PMID: 12807673
-
Focused ion beams techniques for nanomaterials characterization.Microsc Res Tech. 2006 Jul;69(7):538-49. doi: 10.1002/jemt.20324. Microsc Res Tech. 2006. PMID: 16739217 Review.
-
Minimization of focused ion beam damage in nanostructured polymer thin films.Ultramicroscopy. 2011 Feb;111(3):191-9. doi: 10.1016/j.ultramic.2010.11.027. Epub 2010 Dec 1. Ultramicroscopy. 2011. PMID: 21333856
-
Ultrastructural characterization of tooth-biomaterial interfaces prepared with broad and focused ion beams.Dent Mater. 2009 Nov;25(11):1325-37. doi: 10.1016/j.dental.2009.06.002. Epub 2009 Jul 10. Dent Mater. 2009. PMID: 19596422
-
Focused ion beam scanning electron microscopy in biology.J Microsc. 2014 Jun;254(3):109-14. doi: 10.1111/jmi.12127. Epub 2014 Apr 7. J Microsc. 2014. PMID: 24707797 Review.
Cited by
-
ToF-SIMS Depth Profiling of Metal, Metal Oxide, and Alloy Multilayers in Atmospheres of H2, C2H2, CO, and O2.J Am Soc Mass Spectrom. 2022 Jan 5;33(1):31-44. doi: 10.1021/jasms.1c00218. Epub 2021 Dec 22. J Am Soc Mass Spectrom. 2022. PMID: 34936371 Free PMC article.
-
The use of dual beam ESEM FIB to reveal the internal ultrastructure of hydroxyapatite nanoparticle-sugar-glass composites.J Mater Sci Mater Med. 2009 Jan;20(1):203-14. doi: 10.1007/s10856-008-3539-6. Epub 2008 Aug 20. J Mater Sci Mater Med. 2009. PMID: 18712505
-
Advanced preparation of plan-view specimens on a MEMS chip for in situ TEM heating experiments.MRS Bull. 2022;47(4):359-370. doi: 10.1557/s43577-021-00255-5. Epub 2022 Mar 7. MRS Bull. 2022. PMID: 35968543 Free PMC article.
-
Ti and its alloys as examples of cryogenic focused ion beam milling of environmentally-sensitive materials.Nat Commun. 2019 Feb 26;10(1):942. doi: 10.1038/s41467-019-08752-7. Nat Commun. 2019. PMID: 30808943 Free PMC article.
-
Focused Ion Beam Processing for 3D Chiral Photonics Nanostructures.Micromachines (Basel). 2020 Dec 23;12(1):6. doi: 10.3390/mi12010006. Micromachines (Basel). 2020. PMID: 33374782 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources