Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Jan;12(1):64-9.
doi: 10.1097/00005382-199701000-00010.

Azygos arch cannulation by central venous catheters: radiographic detection of malposition and subsequent complications

Affiliations

Azygos arch cannulation by central venous catheters: radiographic detection of malposition and subsequent complications

A A Bankier et al. J Thorac Imaging. 1997 Jan.

Abstract

The aim of this study was to determine the frequency of radiographically evident central venous catheter misplacement in the azygos arch and to analyze whether the frequency of azygos arch cannulation is dependent on the anatomical site of catheter insertion. We reviewed 1,287 postprocedural examinations and 3,441 follow-up examinations. Catheters had been inserted through the left (6%) or right (15%) internal jugular veins and through the left (32%) or right (46%) subclavin veins. Radiographs were analyzed for possible catheter malposition in the azygos arch and for complications related to this malposition. Catheter malposition in the azygos arch was seen on 16/1,287 (1.2%) postprocedural radiographic examinations. Of the 16 malpositioned catheters, 11 (69%) had been inserted in the left subclavian vein, three (19%) in the left jugular vein, two (12%) in the right subclavian vein, and none (0%) in the right jugular vein. There was a statistically significant difference in the frequency of azygos arch cannulation between left- and right-sided catheters (p = 0.001). All complications consisted of venous perforations and were seen in three of 16 cases (19%). Azygos arch cannulation is a rare but hazardous central venous catheter malposition that occurs early after catheter insertion and carries a substantial risk for complication. The risk for azygos arch cannulation is substantially increased if catheters are inserted in left-sided veins. Because of the severity of subsequent complications, radiologists should be vigilant in the detection of this rare malposition.

PubMed Disclaimer

Publication types

LinkOut - more resources