Dentin shear strength: effects of tubule orientation and intratooth location
- PMID: 9002852
- DOI: 10.1016/S0109-5641(96)80077-7
Dentin shear strength: effects of tubule orientation and intratooth location
Abstract
Objectives: Dentin has a highly oriented tubule structure, and the tubule number density and area fraction of intertubular dentin vary with distance from the pulp. This investigation sought to determine the influence of tubule orientation on shear strength of dentin from samples derived at various intratooth locations.
Methods: Third molars were sectioned and prepared to provide samples from two locations (center and cusp) and with one of three specific tubule orientations. In series 1, matched pairs of midcoronal samples were tested using two tubule orientations. A paired t-test was used for statistical analysis. In series 2, three samples from central and cuspal areas were tested using three different tubule orientations. A two-day ANOVA was used for statistical analysis. Each sample had dimensions of approximately 1 x 1 x 5 mm and was tested in a hydrated state by a single plane lap shear method.
Results: The paired dentin samples of the midcoronal dentin in the two orientations had shear strengths of 72.4 +/- 15.6 MPa and 78.4 +/- 13.2 MPa, and were not significantly different (p > 0.05; paired t-test). In the second series, samples from the center location with tubules parallel to the shear plane with applied force in directions rotated by 90 degrees did not exhibit a significant difference (p > 0.05), with an average value of 53.5 +/- 9.5 MPa. Samples oriented with tubules along the long axis of the specimen and tested with shear force applied perpendicular to the tubule direction had significantly higher (p < 0.05; two-way ANOVA) shear strength (78.0 +/- 8.5 MPa). The specimens from the cusp area did not exhibit a statistically significant difference (p > 0.05; two-way ANOVA) with respect to the three orientations (83.6 +/- 8.4; +/- 13.8; 91.8 +/- 12.7 MPa). Cuspal areas were stronger than central areas in two of the three orientations tested.
Significance: Results indicated that the shear strength differs in central and cusp areas and is dependent on dentin tubule orientation in the central area. Shear strengths were much larger than values reported in shear bond strength tests. This suggests that dentin shear strength is far in excess of dentin bond strengths using shear tests, and that fractures through dentin in such result from flaws or stress concentration in the dentin.
Similar articles
-
Comparison of shear and flexural bond strength tests versus failure modes of dentin bonding systems.Am J Dent. 2001 Oct;14(5):297-303. Am J Dent. 2001. PMID: 11803994
-
The bond of resin to different dentin surface characteristics.Oper Dent. 2004 May-Jun;29(3):333-41. Oper Dent. 2004. PMID: 15195735
-
Effect of dentinal tubule orientation on the microtensile bond strength to primary dentin.J Dent Child (Chic). 2003 May-Aug;70(2):139-44. J Dent Child (Chic). 2003. PMID: 14528775
-
Adhesion to tooth structure: a critical review of "macro" test methods.Dent Mater. 2010 Feb;26(2):e38-49. doi: 10.1016/j.dental.2009.11.150. Epub 2009 Dec 11. Dent Mater. 2010. PMID: 20004960 Review.
-
The mechanical properties of human dentin: a critical review and re-evaluation of the dental literature.Crit Rev Oral Biol Med. 2003;14(1):13-29. doi: 10.1177/154411130301400103. Crit Rev Oral Biol Med. 2003. PMID: 12764017 Review.
Cited by
-
The microtensile bond strength test: Its historical background and application to bond testing.Jpn Dent Sci Rev. 2020 Dec;56(1):24-31. doi: 10.1016/j.jdsr.2019.10.001. Epub 2019 Nov 25. Jpn Dent Sci Rev. 2020. PMID: 31827652 Free PMC article. Review.
-
Structure-function relationships in dog dentin.J Biomech. 2022 Aug;141:111218. doi: 10.1016/j.jbiomech.2022.111218. Epub 2022 Jul 8. J Biomech. 2022. PMID: 35834939 Free PMC article.
-
Validity of bond strength tests: A critical review: Part I.J Conserv Dent. 2014 Jul;17(4):305-11. doi: 10.4103/0972-0707.136340. J Conserv Dent. 2014. PMID: 25125840 Free PMC article. Review.
-
Effects of two disinfection/sterilization methods for dentin specimens on dentin permeability.Clin Oral Investig. 2019 Feb;23(2):899-904. doi: 10.1007/s00784-018-2513-z. Epub 2018 Jun 14. Clin Oral Investig. 2019. PMID: 29948279
-
Dentin bond strength after ablation using a CO(2) laser operating at high pulse repetition rates.Proc SPIE Int Soc Opt Eng. 2009 Feb 18;7162:71620F. doi: 10.1117/12.816862. Proc SPIE Int Soc Opt Eng. 2009. PMID: 21892256 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials