Electrochemical studies of zinc in zinc-insulin solution
- PMID: 9008404
- DOI: 10.1039/an9962101789
Electrochemical studies of zinc in zinc-insulin solution
Abstract
The electrochemical determination of zinc arising from zinc-insulin complexes was investigated and it was demonstrated that zinc in zinc-insulin solution can be measured in the presence of dissolved oxygen by square-wave anodic stripping voltammetry (SWASV) at mercury thin-film electrodes on glassy carbon disc minielectrode and cylindrical carbon fibre microelectrode substrates. Reoxidation signals arise from complexed zinc at low insulin concentrations (< 100 nmol l-1) and from labile zinc at higher concentrations; the latter can be quantified through linear calibration curves. Batch injection analysis with SWASV was successfully tested for the determination of zinc in zinc-insulin solutions in small sample volumes. Since intracellularly stored insulin exists in the form of a zinc-insulin complex, these techniques are very promising for the indirect study of insulin release from pancreatic beta-cells.
Similar articles
-
Use of a modified, high-sensitivity, anodic stripping voltammetry method for determination of zinc speciation in the North Atlantic Ocean.Anal Chim Acta. 2008 May 5;614(2):143-52. doi: 10.1016/j.aca.2008.03.006. Epub 2008 Mar 13. Anal Chim Acta. 2008. PMID: 18420044
-
Poly(ester sulphonic acid) coated mercury thin film electrodes: characterization and application in batch injection analysis stripping voltammetry of heavy metal ions.Talanta. 2000 Jan 10;50(6):1223-31. doi: 10.1016/s0039-9140(99)00232-5. Talanta. 2000. PMID: 18967818
-
Detection of secretion from pancreatic islets using chemically modified electrodes.Anal Biochem. 2004 Mar 15;326(2):183-9. doi: 10.1016/j.ab.2003.12.013. Anal Biochem. 2004. PMID: 15003559
-
Economic bismuth-film microsensor for anodic stripping analysis of trace heavy metals using differential pulse voltammetry.Anal Bioanal Chem. 2005 Nov;383(5):839-47. doi: 10.1007/s00216-005-0083-9. Epub 2005 Nov 5. Anal Bioanal Chem. 2005. PMID: 16215756
-
Simultaneous determination of zinc, copper, lead, and cadmium in fuel ethanol by anodic stripping voltammetry using a glassy carbon-mercury-film electrode.Anal Bioanal Chem. 2004 Sep;380(1):135-40. doi: 10.1007/s00216-004-2733-8. Epub 2004 Jul 20. Anal Bioanal Chem. 2004. PMID: 15278344
Cited by
-
Control of pulsatile 5-HT/insulin secretion from single mouse pancreatic islets by intracellular calcium dynamics.J Physiol. 1998 Jul 1;510 ( Pt 1)(Pt 1):135-43. doi: 10.1111/j.1469-7793.1998.135bz.x. J Physiol. 1998. PMID: 9625872 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical