Pelvic lysis and polyethylene wear at 5-8 years in an uncemented total hip
- PMID: 9020220
Pelvic lysis and polyethylene wear at 5-8 years in an uncemented total hip
Abstract
The clinical and radiographic results of 160 primary, uncemented porous coated total hip replacements performed at 3 teaching hospitals were reviewed. Followup was obtained in 132 of 148 (89%) nondeceased patients. The acetabular component is a full hemisphere, fabricated of cobalt chrome with a sintered bead coating and was implanted with screws in all cases. A 32 mm cobalt chrome femoral head was used in all cases. At 2 to 4 years the incidence of pelvic lysis was 0 and no acetabular revisions had been performed. At 5 to 8 years followup, 3 of 132 (2%) femoral stems had been revised, while on the acetabulum side discrete expansile pelvic lytic lesions occurred in 15 cases (11%) with 8 cases (5%) requiring revision. Abrasion of the screwhead against the backside of the polyethylene liner was seen in all retrieved cases and may have contributed to the development of the lytic lesions seen. Use of this uncemented press fit hemispheric acetabular components, using adjunctive screw fixation resulted in an unacceptably high rate of polyethylene wear and aggressive pelvic lysis. While the results on the femoral side were good, the results with this uncemented acetabular system did not represent an improvement over previous cemented or uncemented acetabular components.
Similar articles
-
[Failure of the polyethylene cups directly implanted into bone. A study of 32 Freeman cups after 9 years of followup (6-12 years)].Rev Chir Orthop Reparatrice Appar Mot. 1998 Nov;84(8):700-4. Rev Chir Orthop Reparatrice Appar Mot. 1998. PMID: 10192120 French.
-
The role of acetabular component screw holes and/or screws in the development of pelvic osteolysis.Proc Inst Mech Eng H. 1999;213(2):147-53. doi: 10.1243/0954411991534861. Proc Inst Mech Eng H. 1999. PMID: 10333686
-
Polyethylene wear in uncemented acetabular components.J Bone Joint Surg Br. 1994 Mar;76(2):263-6. J Bone Joint Surg Br. 1994. PMID: 8113288
-
Choosing the socket in total hip arthroplasty.Can J Surg. 1995 Feb;38 Suppl 1:S46-8. Can J Surg. 1995. PMID: 7874628 Review.
-
[Research progress of backside wear in acetabular liners].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2013 Dec;27(12):1453-6. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2013. PMID: 24640364 Review. Chinese.
Cited by
-
Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws.Int Orthop. 2011 Jul;35(7):957-63. doi: 10.1007/s00264-010-1059-8. Epub 2010 Jun 4. Int Orthop. 2011. PMID: 20524114 Free PMC article. Clinical Trial.
-
Experimental and analytical validation of a modular acetabular prosthesis in total hip arthroplasty.J Orthop Surg Res. 2007 May 16;2:7. doi: 10.1186/1749-799X-2-7. J Orthop Surg Res. 2007. PMID: 17506882 Free PMC article.
-
A prospective comparative study of hip resurfacing arthroplasty and large-diameter head metal-on-metal total hip arthroplasty in younger patients-a minimum of five year follow-up.Int Orthop. 2018 Oct;42(10):2323-2327. doi: 10.1007/s00264-018-3819-9. Epub 2018 Feb 18. Int Orthop. 2018. PMID: 29455347
-
Comparison of Different Locking Mechanisms in Total Hip Arthroplasty: Relative Motion between Cup and Inlay.Materials (Basel). 2020 Mar 19;13(6):1392. doi: 10.3390/ma13061392. Materials (Basel). 2020. PMID: 32204382 Free PMC article.
-
Adverse Local Tissue Reaction and Osteolysis After Ceramic-on-Ceramic Total Hip Arthroplasty.Arthroplast Today. 2024 Dec 7;30:101584. doi: 10.1016/j.artd.2024.101584. eCollection 2024 Dec. Arthroplast Today. 2024. PMID: 39717838 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical