Intratracheal instillation versus intratracheal-inhalation of tracer particles for measuring lung clearance function
- PMID: 9028797
- DOI: 10.3109/01902149709046045
Intratracheal instillation versus intratracheal-inhalation of tracer particles for measuring lung clearance function
Abstract
Effective elimination of particles deposited in the respiratory tract is an important defense function to protect the organism from potentially adverse effects of inhaled particles. Delivery of radioactively labeled tracer particles and subsequent measurement in vivo of their retention in different regions of the respiratory tract provides an adequate method for characterizing this defensive function. However, the delivery of such tracer particles by inhalation may result in some external contamination of the animals and requires specific protective measures while working with radioactive aerosols. In this study, 85Sr-labeled tracer particles (3 microns) were administered to the lower respiratory tract of rats by intratracheal inhalation to avoid external contamination, and also by intratracheal instillation in order to compare the 2 technique with respect to their suitability for measuring normal and impaired particle clearance rates. It was postulated that particle clearance function in the alveolar region can be determined equally well with intratracheally instilled particles despite their uneven distribution in the lung. For both techniques, rats were anesthesized with halothane and the particles were administered via oral intubation. Retention in the lower respiratory tract of about 30 micrograms (inhalation) and 6 micrograms (instillation) of the administered particles was followed over a period of 180 days by external counting of lung 85Sr-activity in a collimated detection system. To impair alveolar particle clearance rates, groups of rats were subjected to 12 weeks of inhalation exposure prior to delivery of the tracer particles as follows: (1) sham-exposed control; (2) pigment-grade TiO2 particles to induce lung overload: (3) ultrafine TiO2 particles: (4) crystalline SiO2 particles (cristobalite). The following results were obtained: The long-term retention half-times (T1/2) of the tracer particles reflecting alveolar clearance consistently showed the same ranking of the treatment groups whether measured after intratracheal inhalation or instillation. Control values were 66 and 72 days, respectively, and significantly prolonged long-term clearance was measured by both methods for pigment-grade TiO2 (117 and 99 days), ultrafine TiO2 (541 and 600 days) and SiO2 (1901 and 1368 days). Comparison of these values between the two modes of administration of tracer particles showed no significant differences. In contrast, the short-term T1/2 (mucociliary clearance) of the intratracheally instilled tracer particles in the different treatment groups were variable and did not accurately reflect particle clearance from the conducting airways. However, short-term T1/2 after intratracheal inhalation of tracer particles were consistent with fast conducting airway clearance, and mucociliary clearance appears to be stimulated when alveolar clearance is significantly impaired due to particle overload or to effects of cytotoxic particles. The results suggest that intratracheal instillation of a low dose (< or = 10 micrograms) of tracer particles in the rat provides an adequate method for reliably determining effects of inhaled toxicants on alveolar particle clearance function. Further, intratracheal inhalation of tracer particles is useful for measuring both short-term (mucociliary) and long-term (alveolar) particle clearance rates in the lower respiratory tract of the rat.
Similar articles
-
Significance of particle parameters in the evaluation of exposure-dose-response relationships of inhaled particles.Inhal Toxicol. 1996;8 Suppl:73-89. Inhal Toxicol. 1996. PMID: 11542496 Review.
-
Intratracheal inhalation vs intratracheal instillation: differences in particle effects.Fundam Appl Toxicol. 1997 Dec;40(2):220-7. doi: 10.1006/faat.1997.2390. Fundam Appl Toxicol. 1997. PMID: 9441718
-
Quantitative biokinetics over a 28 day period of freshly generated, pristine, 20 nm titanium dioxide nanoparticle aerosols in healthy adult rats after a single two-hour inhalation exposure.Part Fibre Toxicol. 2019 Jul 9;16(1):29. doi: 10.1186/s12989-019-0303-7. Part Fibre Toxicol. 2019. PMID: 31288843 Free PMC article.
-
Comparative pulmonary toxicity inhalation and instillation studies with different TiO2 particle formulations: impact of surface treatments on particle toxicity.Toxicol Sci. 2005 Dec;88(2):514-24. doi: 10.1093/toxsci/kfi331. Epub 2005 Sep 21. Toxicol Sci. 2005. PMID: 16177240
-
A mechanistic review of particle overload by titanium dioxide.Inhal Toxicol. 2017 Oct-Dec;29(12-14):530-540. doi: 10.1080/08958378.2018.1430192. Inhal Toxicol. 2017. PMID: 29458306 Review.
Cited by
-
Novel lanthanide-labeled metal oxide nanoparticles improve the measurement of in vivo clearance and translocation.Part Fibre Toxicol. 2013 Jan 10;10:1. doi: 10.1186/1743-8977-10-1. Part Fibre Toxicol. 2013. PMID: 23305071 Free PMC article.
-
Vagal control of mucociliary clearance in murine lungs: a study in a chronic preparation.Auton Neurosci. 2010 Apr 19;154(1-2):74-8. doi: 10.1016/j.autneu.2009.12.002. Epub 2010 Jan 3. Auton Neurosci. 2010. PMID: 20051324 Free PMC article.
-
Inhalation Exposure to Carbon Nanotubes (CNT) and Carbon Nanofibers (CNF): Methodology and Dosimetry.J Toxicol Environ Health B Crit Rev. 2015;18(3-4):121-212. doi: 10.1080/10937404.2015.1051611. J Toxicol Environ Health B Crit Rev. 2015. PMID: 26361791 Free PMC article.
-
Intratracheal instillation versus intratracheal inhalation: influence of cytokines on inflammatory response.Environ Health Perspect. 1997 Sep;105 Suppl 5(Suppl 5):1265-71. doi: 10.1289/ehp.97105s51265. Environ Health Perspect. 1997. PMID: 9400736 Free PMC article.
-
Nanometer-long Ge-imogolite nanotubes cause sustained lung inflammation and fibrosis in rats.Part Fibre Toxicol. 2014 Dec 14;11:67. doi: 10.1186/s12989-014-0067-z. Part Fibre Toxicol. 2014. PMID: 25497478 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources