Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996;15(5):589-94.
doi: 10.1016/0750-7658(96)82123-x.

[Effects of propofol on blood concentration of cyclosporine]

[Article in French]
Affiliations

[Effects of propofol on blood concentration of cyclosporine]

[Article in French]
J P Pertek et al. Ann Fr Anesth Reanim. 1996.

Abstract

Objective: This study was designed to assess whether propofol modifies the blood concentrations of cyclosporine and lipoproteins, which bind cyclosporine.

Study design: Prospective open study.

Patients: Fifteen consecutive grafted patients, scheduled for surgery allowing them to resume their oral treatment postoperatively. Their immunosuppressive treatment, included cyclosporine (Cy A), at a steady-state dosage.

Methods: Blood samples were drawn and residual Cy A blood concentrations were measured the days before and after anaesthesia and before and immediately after discontinuing the propofol infusion. Serum triglycerides, cholesterol, high-density lipoprotein (HDL) concentrations were measured before and immediately after discontinuing the propofol infusion.

Results: The 15 patients were given propofol by infusion for 30-210 min (mean 85 +/- 59 min). They received a total dose of propofol of 696 +/- 497 mg, a total fentanyl dose of 175 +/- 82 micrograms, and a total midazolam dose of 2.8 +/- 0.8 mg. The residual cyclosporine blood concentrations were similar the day before (142 +/- 47 ng.mL-1) and following anaesthesia (128 +/- 46 ng.mL-1) (P = 0.08). Serum cholesterol concentrations were not significantly influenced by propofol infusion, but serum triglycerides levels increased (1.46 +/- 0.66 vs 1.97 +/- 0.81 g.L-1), and HDL and LDL levels decreased (0.54 +/- 0.20 vs 0.47 +/- 0.18 g.L-1; 1.44 +/- 0.42 vs 1.28 +/- 0.37 g.L-1).

Conclusion: Propofol by infusion does not modify the cyclosporine concentration. It is concluded that propofol may be a suitable agent for intravenous anaesthesia in cyclosporine treated patients, provided a close postoperative monitoring of cyclosporine blood concentrations is maintained.

PubMed Disclaimer

Publication types

LinkOut - more resources