Comparison of p53 immunoreactivity in fresh-cut versus stored slides with and without microwave heating
- PMID: 9071730
Comparison of p53 immunoreactivity in fresh-cut versus stored slides with and without microwave heating
Abstract
Because of technical problems in immunohistochemical staining of archival material, antigens can be masked or lost. A recent study reported diminished p53 immunoreactivity in slides that had been sectioned from parafinn-embedded tissue blocks and stored at room temperature. To investigate this issue, we performed immunohistochemical staining with use of a p53 monoclonal antibody (DO7) in 13 head and neck squamous cell carcinoma (HNSCC) and 13 non-small-cell lung carcinomas. The fresh-cut and stored slides were simultaneously stained with and without the use of a microwave heating (MWH) technique, and we compared the results of p53 immunostaining. The stored slides were sectioned from paraffin blocks 4 to 25 years old and kept at room temperature for 6 to 48 months. The slides were blindly evaluated for percentage of positivity and staining intensity. Twelve HNSCCs and six lung carcinomas showed p53 positivity. The stored slides showed a considerable decrease in staining intensity (P = 0.039), compared with fresh-cut slides. The difference in the percentage of positivity between the stored and fresh-cut slides was statistically significant, but the mean value of the difference was only 3.6%, which might not be meaningful for semiquantitation of immunostaining. MWH greatly enhanced staining intensity and percentage of positivity for both stored and fresh-cut slides. When MWH was applied, no significant difference in staining intensity (P = 0.063) was detected in fresh-cut versus stored slides, but the difference in the percentage of positivity was statistically significant (mean value, 3.1%). Individual cases showed a consistent p53 status regardless of the MWH treatment, storage duration, or age of the blocks. This study demonstrated a considerable decrease in p53 immunoreactivity in stored slides. Because the MWH successfully retrieved the p53 antigen without causing a change in p53 status, stored slides combined with an MWH antigen retrieval technique in a metal-containing solution should provide p53 immunostaining results similar to those from fresh-cut slides, as long as staining intensity is not a sole study parameter.
Similar articles
-
Methods in pathology. Optimization of proliferating cell nuclear antigen immunohistochemical staining by microwave heating in zinc sulfate solution.Mod Pathol. 1994 Feb;7(2):242-8. Mod Pathol. 1994. PMID: 7516561
-
Immunohistochemical detection of p53 protein in archival tissues from squamous cell carcinomas of the oral cavity using wet autoclave antigen retrieval.J Pathol. 1995 May;176(1):69-75. doi: 10.1002/path.1711760111. J Pathol. 1995. PMID: 7616359
-
p53 immunolabeling in archival paraffin-embedded tissues: optimal protocol based on microwave heating for eight antibodies on lung carcinomas.Mod Pathol. 1994 Oct;7(8):853-9. Mod Pathol. 1994. PMID: 7530851
-
p53 and P-glycoprotein expression do not correlate with survival in nonsmall cell lung cancer: a long-term study and literature review.Mod Pathol. 1999 Dec;12(12):1158-66. Mod Pathol. 1999. PMID: 10619270 Review.
-
Comparison of automated cellular imaging system and manual microscopy for immunohistochemically stained cryostat sections of lung cancer specimens applying p53, ki-67 and p120.Oncol Rep. 2003 Jan-Feb;10(1):15-20. Oncol Rep. 2003. PMID: 12469137 Review.
Cited by
-
Epitope Preservation Methods for Tissue Microarrays: Longitudinal Prospective Study.Am J Clin Pathol. 2017 Nov 2;148(5):380-389. doi: 10.1093/ajcp/aqx062. Am J Clin Pathol. 2017. PMID: 29106459 Free PMC article.
-
Factors affecting immunoreactivity in long-term storage of formalin-fixed paraffin-embedded tissue sections.Histochem Cell Biol. 2015 Jul;144(1):93-9. doi: 10.1007/s00418-015-1316-4. Epub 2015 Mar 11. Histochem Cell Biol. 2015. PMID: 25757745
-
Accelerated instability testing reveals quantitative mass spectrometry overcomes specimen storage limitations associated with PD-L1 immunohistochemistry.Lab Invest. 2020 Jun;100(6):874-886. doi: 10.1038/s41374-019-0366-y. Epub 2020 Jan 2. Lab Invest. 2020. PMID: 31896815 Free PMC article.
-
Soft X-Ray Microscopy Radiation Damage On Fixed Cells Investigated With Synchrotron Radiation FTIR Microscopy.Sci Rep. 2015 May 14;5:10250. doi: 10.1038/srep10250. Sci Rep. 2015. PMID: 25974639 Free PMC article.
-
Effects of long-term storage on the detection of proteins, DNA, and mRNA in tissue microarray slides.J Histochem Cytochem. 2011 Dec;59(12):1113-21. doi: 10.1369/0022155411423779. J Histochem Cytochem. 2011. PMID: 22147608 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Medical
Research Materials
Miscellaneous