An optimized approach to membrane capacitance estimation using dual-frequency excitation
- PMID: 9083668
- PMCID: PMC1184358
- DOI: 10.1016/S0006-3495(97)78810-6
An optimized approach to membrane capacitance estimation using dual-frequency excitation
Abstract
We present an optimized solution to the problem of membrane impedance estimation when a patch-clamped cell is stimulated by a dual-frequency, sinusoidal excitation. The complete data set of raw whole-cell current samples is typically reduced, via digital lock-in detection, to measurements of the complex cell model admittance at the two stimulus frequencies. We describe a statistical model of both data sets and demonstrate that the admittance data adequately represent the essential features obtained from the raw data. The parameter estimates obtained by a nonlinear weighted least-squares solution (NWLS), which under normal recording conditions is equivalent to the maximum likelihood solution, essentially obtain the theoretical lower bound on variance established by the Cramér-Rao bound. Our software implementation of the NWLS solution produces estimates of the cell model parameters that are less noisy than other dual-frequency systems. Our system can be used 1) to measure slow changes in membrane capacitance-in the face of large, slow changes in membrane resistance, 2) to detect with confidence capacitance changes expected from the exocytosis of moderate-sized dense core granules, and 3) to reduce the cross-talk between transient changes in membrane conductance and membrane capacitance.
Similar articles
-
Influence of conductance changes on patch clamp capacitance measurements using a lock-in amplifier and limitations of the phase tracking technique.Biophys J. 1995 Dec;69(6):2808-22. doi: 10.1016/S0006-3495(95)80154-2. Biophys J. 1995. PMID: 8599687 Free PMC article.
-
The noise of membrane capacitance measurements in the whole-cell recording configuration.Biophys J. 2000 Oct;79(4):2162-70. doi: 10.1016/S0006-3495(00)76464-2. Biophys J. 2000. PMID: 11023920 Free PMC article.
-
Measurements of membrane patch capacitance using a software-based lock-in system.Pflugers Arch. 2007 May;454(2):335-44. doi: 10.1007/s00424-006-0191-1. Epub 2007 Jan 6. Pflugers Arch. 2007. PMID: 17206448
-
Capacitance measurements. An analysis of the phase detector technique used to study exocytosis and endocytosis.Biophys J. 1988 Jun;53(6):885-92. doi: 10.1016/S0006-3495(88)83169-2. Biophys J. 1988. PMID: 3395658 Free PMC article.
-
A physiological view of the central and peripheral mechanisms that regulate the release of catecholamines at the adrenal medulla.Acta Physiol (Oxf). 2008 Feb;192(2):287-301. doi: 10.1111/j.1748-1716.2007.01807.x. Epub 2007 Nov 15. Acta Physiol (Oxf). 2008. PMID: 18005392 Review.
Cited by
-
Increased islet apoptosis in Pdx1+/- mice.J Clin Invest. 2003 Apr;111(8):1147-60. doi: 10.1172/JCI16537. J Clin Invest. 2003. PMID: 12697734 Free PMC article.
-
Determination of cell capacitance using the exact empirical solution of partial differential Y/partial differential Cm and its phase angle.Biophys J. 2004 Jul;87(1):714-27. doi: 10.1529/biophysj.103.033993. Biophys J. 2004. PMID: 15240504 Free PMC article.
-
Robust, high-resolution, whole cell patch-clamp capacitance measurements using square wave stimulation.Biophys J. 2001 Aug;81(2):937-48. doi: 10.1016/S0006-3495(01)75752-9. Biophys J. 2001. PMID: 11463636 Free PMC article.
-
System for dynamic measurements of membrane capacitance in intact epithelial monolayers.Biophys J. 1998 Dec;75(6):2743-56. doi: 10.1016/S0006-3495(98)77718-5. Biophys J. 1998. PMID: 9826597 Free PMC article.
-
A large pool of releasable vesicles in a cortical glutamatergic synapse.Proc Natl Acad Sci U S A. 2003 Jul 22;100(15):8975-80. doi: 10.1073/pnas.1432836100. Epub 2003 Jun 18. Proc Natl Acad Sci U S A. 2003. PMID: 12815098 Free PMC article.
References
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources