Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 Mar-Apr;7(2):331-8.
doi: 10.1002/jmri.1880070213.

Comparison of albumin-(Gd-DTPA)30 and Gd-DTPA-24-cascade-polymer for measurements of normal and abnormal microvascular permeability

Affiliations
Comparative Study

Comparison of albumin-(Gd-DTPA)30 and Gd-DTPA-24-cascade-polymer for measurements of normal and abnormal microvascular permeability

H C Roberts et al. J Magn Reson Imaging. 1997 Mar-Apr.

Abstract

The purpose of this study was to compare a new MR macromolecular contrast medium (MMCM), gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA)-24-cascade-polymer, to a well-studied prototype MMCM, for the potential of distinguishing tissues of varying endothelial permeability. Three tissue models of varying capillary permeability were studied in a total of 46 rats: normal myocardium (normal capillaries), subcutaneously implanted adenocarcinoma (mild capillary leak), and reperfused infarcted myocardium (high capillary leak). TI-weighted MRI was performed before and dynamically after injection of either albumin-(Gd-DTPA)30 or the cascade polymer (each .02 mmol gadolinium [Gd] per kg). Data analysis based on a two-compartment kinetic model yielded estimates of fractional blood volume (BV) (percentage) and fractional leak rate (FLR) (1 per hour). Permeability to the cascade polymer as reflected in FLR was considerable in normal myocardium (8.24 per hour), of similar value in tumors (8.55 per hour), but significantly greater in infarcted myocardium (39.17 per hour, P < .01) versus normal myocardium. The larger albumin-(Gd-DTPA)30 demonstrated minimal extravasation in normal myocardium (FLR .33 per hour); FLR in tumors was 100% higher (.66 per hour, P < .002) and FLR in reperfused capillaries was significantly greater (7.94 per hour, P < .001). Based on capillary permeability measurements, the cascade polymer may have limited utility for detection of mildly increased microvascular permeabilities. For severe tissue injury, the cascade polymer can resolve abnormal microvascular integrity.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources