Reoperation for hemolytic, anaemia complicating mitral valve repair
- PMID: 9105812
- DOI: 10.1016/s1010-7940(96)01091-3
Reoperation for hemolytic, anaemia complicating mitral valve repair
Abstract
Objective: To identify the possible cause(s) of hemolysis after mitral valve repair for mitral regurgitation (MR) and to evaluate the late outcome of surgical treatment.
Methods: We reviewed all patients who had reoperation after valve repair for mitral regurgitation. Ten patients had reoperation because of hemolytic anaemia. The diagnosis of hemolysis was made by decreased serum haptoglobin, elevation of serum lactate dehydrogenase (LDH), and schistocytosis. No other causes of anaemia or hemolysis were identified in these six men and four women (ages 35-84 years; median 59 years). Interval between initial mitral valve repair and reoperation ranged from 40 to 165 days (median 87 days), and prior to reoperation, red cell transfusions (range 2-12 units; median 5 units) were required in all patients. Seven patients were symptomatic: two complained of easy fatigability and five were severely limited. Transesophageal echocardiogram during hemolytic evaluation showed only mild MR in two patients, moderate in five, moderately severe in two and severe in one.
Results: Etiology of hemolysis was suggested from echocardiography and confirmed at reoperation. In one patient, an eccentric MR jet struck a pledget of a commissural annuloplasty. In the remaining nine patients, the regurgitant jet struck a non-endothelialized portion of the annuloplasty ring (Carpentier-Edwards n = 5; Duran n = 2; Cosgrove-Edwards n = 2). Seven patients had prosthetic replacement and three patients had re-repair. There were no operative deaths and all patients had resolution of hemolytic anaemia.
Conclusions: Relatively minor degrees of regurgitation after mitral valve repair can produce hemolytic anaemia which is manifested within the first few postoperative months. Most patients are highly symptomatic because of anaemia. The mechanism of red cell destruction is a high velocity eccentric stream of blood impacting on a small area of a prosthetic ring or pledget. This process retards endothelialization of the ring. Reoperation with re-repair or mitral valve replacement is safe and effectively relieves the hemolysis.
Similar articles
-
Mechanism of hemolysis after mitral valve repair and new surgical management: prosthetic annuloplasty ring covered with autologous pericardium.J Heart Valve Dis. 2005 Sep;14(5):588-91. J Heart Valve Dis. 2005. PMID: 16245496
-
Reoperation after valve repair for mitral regurgitation: early and intermediate results.J Thorac Cardiovasc Surg. 1996 Jun;111(6):1177-83; discussion 1183-4. doi: 10.1016/s0022-5223(96)70219-2. J Thorac Cardiovasc Surg. 1996. PMID: 8642818
-
Hemolysis after mitral valve repair: mechanisms and treatment.Ann Thorac Surg. 2004 Jan;77(1):191-5. doi: 10.1016/s0003-4975(03)01455-3. Ann Thorac Surg. 2004. PMID: 14726060
-
Haemolysis following mitral valve repair.J Cardiovasc Surg (Torino). 1992 Sep-Oct;33(5):568-9. J Cardiovasc Surg (Torino). 1992. PMID: 1447274 Review.
-
Hemolysis after mitral valve repair.J Card Surg. 2013 Mar;28(2):129-32. doi: 10.1111/jocs.12060. Epub 2013 Jan 13. J Card Surg. 2013. PMID: 23311693 Review.
Cited by
-
Severe haemolytic anaemia after valvuloplasty and annuloplasty.BMJ Case Rep. 2010 Nov 9;2010:bcr0920081022. doi: 10.1136/bcr.09.2008.1022. BMJ Case Rep. 2010. PMID: 22789556 Free PMC article.
-
Percutaneous closure of paravalvular leak in the treatment of anemia of mixed etiology in a patient with diabetic complications and chronic inflammation.J Geriatr Cardiol. 2016 Oct;13(10):866-868. doi: 10.11909/j.issn.1671-5411.2016.10.006. J Geriatr Cardiol. 2016. PMID: 27928229 Free PMC article. No abstract available.
-
A rare case of hemolytic anemia in a pediatric patient due to ring dehiscence after mitral valve repair: utility of real-time three-dimensional imaging and management.Pediatr Cardiol. 2014 Jan;35(1):180-2. doi: 10.1007/s00246-013-0787-0. Epub 2013 Sep 13. Pediatr Cardiol. 2014. PMID: 24030589
-
When and how does nonstructural mechanical prosthetic heart valve dysfunction occur?Jpn J Thorac Cardiovasc Surg. 2003 Aug;51(8):355-60. doi: 10.1007/BF02719467. Jpn J Thorac Cardiovasc Surg. 2003. PMID: 12962412
-
Redo Mitral and Tricuspid Valve Surgery for Hemolytic Anemia, Following Hematuria and Anemia.JACC Case Rep. 2024 Oct 16;29(20):102619. doi: 10.1016/j.jaccas.2024.102619. eCollection 2024 Oct 16. JACC Case Rep. 2024. PMID: 39534619 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical