Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris
- PMID: 9113539
- DOI: 10.1016/s0883-5403(97)90021-8
Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris
Abstract
Between 1985 and 1990, 108 consecutive Harris-Galante I (Zimmer, Warsaw, IN) total hip arthroplasties were performed by four surgeons at a single hospital. At the time of follow-up evaluation, 80 hips were available for review. The mean rate of linear wear was 0.15 mm/y, mean rate of three-dimensional femoral head displacement was 0.21 mm/y, and mean rate of volumetric wear was 121 mm3/y. Eight hips (10%) in this series had radiologic osteolysis around either the femoral or acetabular component. A significantly greater volumetric wear rate was found in patients who were younger, those with a higher activity level, those who received a 32-mm-diameter femoral head, and those with vertical orientation of their acetabular component. No relationship could be made with patient weight, gender, Harris hip score, or cup diameter.
Similar articles
-
Measurement of polyethylene wear in acetabular components inserted with and without cement. A randomized trial.J Bone Joint Surg Am. 1997 May;79(5):682-9. doi: 10.2106/00004623-199705000-00007. J Bone Joint Surg Am. 1997. PMID: 9160940 Clinical Trial.
-
Alumina Delta-on-Highly Crosslinked-Remelted Polyethylene Bearing in Cementless Total Hip Arthroplasty in Patients Younger than 50 Years.J Arthroplasty. 2016 Dec;31(12):2800-2804. doi: 10.1016/j.arth.2016.05.020. Epub 2016 May 18. J Arthroplasty. 2016. PMID: 27378639
-
Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.Clin Orthop Relat Res. 2016 Feb;474(2):365-71. doi: 10.1007/s11999-015-4319-5. Clin Orthop Relat Res. 2016. PMID: 25903943 Free PMC article.
-
High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips.Acta Orthop. 2006 Aug;77(4):575-84. doi: 10.1080/17453670610012638. Acta Orthop. 2006. PMID: 16929433 Review.
-
Late failure of the polyethylene liner fixation in an uncemented total hip arthroplasty.J Arthroplasty. 1999 Apr;14(3):391-6. doi: 10.1016/s0883-5403(99)90070-0. J Arthroplasty. 1999. PMID: 10220198 Review.
Cited by
-
Adapting hip arthroplasty practices during the COVID-19 pandemic: Assessing the impact of outpatient care sudden increase on early complications and clinical outcomes.SICOT J. 2024;10:1. doi: 10.1051/sicotj/2023037. Epub 2024 Jan 9. SICOT J. 2024. PMID: 38193980 Free PMC article.
-
The Müller self-locking cemented total hip prosthesis with polyethylene liner: After twenty years, what did they become?Int Orthop. 2017 Jan;41(1):47-54. doi: 10.1007/s00264-016-3191-6. Epub 2016 Apr 25. Int Orthop. 2017. PMID: 27112946
-
Alumina-on-alumina THA performed in patients younger than 30 years: a 10-year minimum followup study.Clin Orthop Relat Res. 2012 Dec;470(12):3530-6. doi: 10.1007/s11999-012-2493-2. Epub 2012 Jul 24. Clin Orthop Relat Res. 2012. PMID: 22826015 Free PMC article.
-
Activity-related Changes in Cobalt Levels in a Total Hip with a Modular Femoral Stem: A Case Report.J Orthop Case Rep. 2018 Jan-Feb;8(1):44-47. doi: 10.13107/jocr.2250-0685.992. J Orthop Case Rep. 2018. PMID: 29854692 Free PMC article.
-
A comparison of two different navigated hip replacement techniques on leg length discrepancy.J Orthop. 2018 Feb 21;15(3):765-767. doi: 10.1016/j.jor.2018.02.005. eCollection 2018 Sep. J Orthop. 2018. PMID: 29946201 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical