Development of a reverse transcriptase PCR-enzyme-linked immunosorbent assay for quantification of human immunodeficiency virus type 1 RNA in plasma: comparison with commercial quantitative assays
- PMID: 9114417
- PMCID: PMC232739
- DOI: 10.1128/jcm.35.5.1251-1254.1997
Development of a reverse transcriptase PCR-enzyme-linked immunosorbent assay for quantification of human immunodeficiency virus type 1 RNA in plasma: comparison with commercial quantitative assays
Abstract
A quantitative reverse transcriptase PCR assay with automated detection by nonradioactive hybridization was developed for the determination of human immunodeficiency virus (HIV) type 1 RNA levels. This assay is based on the use of an external standard curve with an internal standard. The accuracy of quantification was verified by comparison with reference commercial tests, the Chiron branched-DNA and Roche AMPLICOR HIV MONITOR assays. This assay was able to quantify viremia in patients with CD4 cell numbers below and above 500/mm3 and to quantify some HIV strains which could not be titrated by the MONITOR assay.
Similar articles
-
Comparison of NucliSens and Amplicor monitor assays for quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma of persons with HIV-1 subtype A infection in Abidjan, Côte d'Ivoire.J Clin Microbiol. 1998 Sep;36(9):2495-8. doi: 10.1128/JCM.36.9.2495-2498.1998. J Clin Microbiol. 1998. PMID: 9705381 Free PMC article.
-
Comparison of three different commercial methods for measuring plasma viraemia in patients infected with non-B HIV-1 subtypes.Eur J Clin Microbiol Infect Dis. 1999 Apr;18(4):256-9. doi: 10.1007/s100960050273. Eur J Clin Microbiol Infect Dis. 1999. PMID: 10385013
-
Evaluation of three different commercial procedures for quantifying human immunodeficiency virus type-1 RNA levels.New Microbiol. 1999 Jan;22(1):1-9. New Microbiol. 1999. PMID: 10190111
-
Comparison of three commercial assays for the quantification of HIV-1 RNA in plasma from individuals infected with different HIV-1 subtypes.J Clin Virol. 1999 Oct;14(2):87-94. doi: 10.1016/s1386-6532(99)00053-0. J Clin Virol. 1999. PMID: 10588451
-
Quantitative and cost comparison of ultrasensitive human immunodeficiency virus type 1 RNA viral load assays: Bayer bDNA quantiplex versions 3.0 and 2.0 and Roche PCR Amplicor monitor version 1.5.J Clin Microbiol. 2000 Mar;38(3):1113-20. doi: 10.1128/JCM.38.3.1113-1120.2000. J Clin Microbiol. 2000. PMID: 10699005 Free PMC article.
Cited by
-
Clinical evaluation of an in-house reverse transcription-competitive PCR for quantitation of human immunodeficiency virus type 1 RNA in plasma.J Clin Microbiol. 1999 Feb;37(2):333-8. doi: 10.1128/JCM.37.2.333-338.1999. J Clin Microbiol. 1999. PMID: 9889213 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials