Radiographic detection of cavitation in approximal surfaces of primary teeth using a digital storage phosphor system and conventional film, and the relationship between cavitation and radiographic lesion depth: an in vitro study
- PMID: 9115972
- DOI: 10.1111/j.1365-263x.1996.tb00236.x
Radiographic detection of cavitation in approximal surfaces of primary teeth using a digital storage phosphor system and conventional film, and the relationship between cavitation and radiographic lesion depth: an in vitro study
Abstract
The need for operative treatment of approximal carious lesions may depend on whether or not the surface is cavitated. The aims of this in vitro study were to compare the accuracy of cavity detection in approximal surfaces of primary molars using a storage phosphor system (Digora) and Ektaspeed Plus film, and to relate radiographic lesion depth to the presence or absence of cavitation in the tooth surface. The material consisted of 72 approximal surfaces in 46 exfoliated/extracted primary molars. The teeth were radiographed using Ektaspeed Plus film and then the Digora system with 10% of the film exposure dose. Three examiners independently scored the radiographs for the presence or absence of cavitation on a 5-point confidence scale and for lesion depth on a four-category disease severity scale. Validation of the radiographic diagnosis of cavitation was done by inspecting the dried and cleaned surfaces in direct light using a sharp probe. The surfaces were scored: 0 = sound, 1 = discoloration without cavitation, 2 = cavitation. Diagnostic accuracy of the two radiographic methods was evaluated by ROC curve analysis. There was no statistically significant difference between the accuracy of the two methods for detection of cavitation. There was also no significant difference in the proportion of lesions in outer enamel, inner enamel and dentine detected by the two methods. The majority of lesions diagnosed radiographically to be in dentine were cavitated.
Similar articles
-
Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.Dentomaxillofac Radiol. 2021 Jul 1;50(5):20210010. doi: 10.1259/dmfr.20210010. Epub 2021 Mar 4. Dentomaxillofac Radiol. 2021. PMID: 33661697 Free PMC article. Review.
-
In vitro comparison of D- and E-speed film radiography, RVG, and visualix digital radiography for the detection of enamel approximal and dentinal occlusal caries lesions.Caries Res. 1994;28(5):363-7. doi: 10.1159/000262002. Caries Res. 1994. PMID: 8001059
-
Approximal caries depth assessment with storage phosphor versus film radiography. Evaluation of the caries-specific Oslo enhancement procedure.Caries Res. 2000 Nov-Dec;34(6):448-53. doi: 10.1159/000016622. Caries Res. 2000. PMID: 11093017
-
Accuracy of caries detection with four storage phosphor systems and E-speed radiographs.Dentomaxillofac Radiol. 2002 May;31(3):170-5. doi: 10.1038/sj/dmfr/4600686. Dentomaxillofac Radiol. 2002. PMID: 12058264
-
Radiographic display of carious lesions and cavitation in approximal surfaces: Advantages and drawbacks of conventional and advanced modalities.Acta Odontol Scand. 2014 May;72(4):251-64. doi: 10.3109/00016357.2014.888757. Epub 2014 Feb 10. Acta Odontol Scand. 2014. PMID: 24512205 Review.
Cited by
-
Accuracy of direct digital radiography for detecting occlusal caries in primary teeth compared with conventional radiography and visual inspection: an in vitro study.Dentomaxillofac Radiol. 2010 Sep;39(6):362-7. doi: 10.1259/dmfr/22865872. Dentomaxillofac Radiol. 2010. PMID: 20729186 Free PMC article.
-
Comparison of digital systems and conventional dental film for the detection of approximal enamel caries.Dentomaxillofac Radiol. 2010 Oct;39(7):431-6. doi: 10.1259/dmfr/94985823. Dentomaxillofac Radiol. 2010. PMID: 20841461 Free PMC article.
-
Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.Clin Oral Investig. 2011 Dec;15(6):901-7. doi: 10.1007/s00784-010-0461-3. Epub 2010 Sep 14. Clin Oral Investig. 2011. PMID: 20838834
-
Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors.Dentomaxillofac Radiol. 2013;42(1):39458105. doi: 10.1259/dmfr/39458105. Epub 2012 Jul 27. Dentomaxillofac Radiol. 2013. PMID: 22842638 Free PMC article.
-
Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.Dentomaxillofac Radiol. 2021 Jul 1;50(5):20210010. doi: 10.1259/dmfr.20210010. Epub 2021 Mar 4. Dentomaxillofac Radiol. 2021. PMID: 33661697 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical