Non-breath-hold fast spin-echo versus breath-hold fast spin-echo and spoiled gradient-recalled echo MR imaging in the detection of hepatic tumors: correlation with surgical findings
- PMID: 9129411
- DOI: 10.2214/ajr.168.5.9129411
Non-breath-hold fast spin-echo versus breath-hold fast spin-echo and spoiled gradient-recalled echo MR imaging in the detection of hepatic tumors: correlation with surgical findings
Abstract
Objective: Our objective was to compare the sensitivity of non-breath-hold T2-weighted fast spin-echo with and without fat suppression, breath-hold T2-weighted fast spin-echo without fat suppression, and spoiled gradient-recalled echo (GRE) MR imaging for detecting hepatic tumors using surgical findings as the standard of reference.
Subjects and methods: Eighteen patients with 36 surgically proven hepatic tumors had non-breath-hold T2-weighted fast spin-echo (6000/117 [TR/effective TE; echo train length, 16) MR imaging with and without fat suppression, breath-hold T2-weighted fast spin-echo MR imaging (2700/105; echo train length, 20), and spoiled GRE images (10.1/1.9; flip angle, 30 degrees) obtained before and after injection of a gadolinium chelate. Images were analyzed separately by two independent readers, with disagreements resolved by consensus reading.
Results: Non-breath-hold T2-weighted fast spin-echo MR imaging with and without fat suppression depicted 22 (61%; 95% confidence interval [CI], 43-77%) and 20 (56%; 95% CI, 37-72%) of 36 hepatic tumors, respectively. Breath-hold T2-weighted fast spin-echo imaging allowed detection of 19 (53%; 95% CI, 35-69%) of 36 hepatic tumors. Unenhanced and gadolinium chelate-enhanced spoiled GRE images allowed depiction of 18 (50%; 95% CI, 33-67%) and 29 (81%; 95% CI, 63-91%) of 36 hepatic tumors, respectively. Gadolinium chelate-enhanced spoiled GRE images allowed depiction of significantly more hepatic tumors than any of the other pulse sequences.
Conclusion: Gadolinium chelate-enhanced spoiled GRE imaging is more sensitive than T2-weighted MR imaging obtained with a breath-hold or a non-breath-hold technique.
Similar articles
-
Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.AJR Am J Roentgenol. 1996 May;166(5):1115-21. doi: 10.2214/ajr.166.5.8615254. AJR Am J Roentgenol. 1996. PMID: 8615254
-
MR diagnosis of hepatic metastases from neuroendocrine tumors versus hemangiomas: relative merits of dynamic gadolinium chelate-enhanced gradient-recalled echo and unenhanced spin-echo images.AJR Am J Roentgenol. 1995 Dec;165(6):1407-13. doi: 10.2214/ajr.165.6.7484575. AJR Am J Roentgenol. 1995. PMID: 7484575
-
Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.AJR Am J Roentgenol. 1993 Mar;160(3):501-9. doi: 10.2214/ajr.160.3.8381572. AJR Am J Roentgenol. 1993. PMID: 8381572
-
Fast magnetic resonance imaging of liver.Eur J Radiol. 1999 Mar;29(3):186-210. doi: 10.1016/s0720-048x(98)00176-4. Eur J Radiol. 1999. PMID: 10399607 Review.
-
MRI of pancreatic tumors.Eur Radiol. 1997;7(6):875-86. doi: 10.1007/s003300050221. Eur Radiol. 1997. PMID: 9228103 Review.
Cited by
-
The detection and discrimination of malignant and benign focal hepatic lesions: T2 weighted vs diffusion-weighted MRI.Br J Radiol. 2011 Apr;84(1000):319-26. doi: 10.1259/bjr/50130643. Epub 2010 Oct 19. Br J Radiol. 2011. PMID: 20959371 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical