The heart muscle's putative "secondary structure'. Functional implications of a band-like anisotropy
- PMID: 9134619
The heart muscle's putative "secondary structure'. Functional implications of a band-like anisotropy
Abstract
Opinions are divided as to whether the rope-like secondary structure, which Torrent-Guasp dissected out of the myocardial body by the blunt unwinding technique (BUT) reveals some kind of functional compartmentation of the heart muscle. The myocardial fibres are aligned parallel to the fibre disruption (cleavage) plane, along which the band has been prepared but they are not necessarily aligned parallel to the long axis of the band. Inconsistencies in the myocardial rope model arise from the obligatory zones of transmural inflection, which are obvious in the base and the apex of both ventricles. They are, however, merely discernible in the midzone of the left ventricular cone. The investigator experienced in BUT knows that the cleavage plane is not unique. We doubt the assumption that the rope structure is the predominant stress transmission pathway, because the fibre strand peel-off technique (SPOT) delivers irregular fibre disruption planes which are definitely different from those which Torrent-Guasp prepares. The rope-like fibre arrangement could be just a redundant structure, a remnant of past developmental steps without, however, any functional implication to the human heart. On the other hand, peeling-off fibre strands from the ventricular wall produces deeply perforating, i.e., oblique transmurally grooved surfaces. Putative functions of force transmission in an oblique transmural direction are (1) ventricular dilation as a function of the variable inclination angle with respect to the epicardial surface, (2) monitoring of ventricular wall stress and ventricular size and (3) segmental stiffening which could serve other dependent segments as a punctum fixum.
Similar articles
-
The heart's fibre alignment assessed by comparing two digitizing systems. Methodological investigation into the inclination angle towards wall thickness.Technol Health Care. 1997 Apr;5(1-2):65-77. Technol Health Care. 1997. PMID: 9134620
-
The anisotropic structure of the human left and right ventricles.Technol Health Care. 1997 Apr;5(1-2):29-43. Technol Health Care. 1997. PMID: 9134617
-
The helical ventricular myocardial band of Torrent-Guasp.Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu. 2007:52-60. doi: 10.1053/j.pcsu.2007.01.006. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu. 2007. PMID: 17433993 Review.
-
The assessment of intramural stress alignment on the beating heart in situ using micro-ergometry: functional implications.Technol Health Care. 1997 Apr;5(1-2):115-22. Technol Health Care. 1997. PMID: 9134623
-
The helical ventricular myocardial band: global, three-dimensional, functional architecture of the ventricular myocardium.Eur J Cardiothorac Surg. 2006 Apr;29 Suppl 1:S21-40. doi: 10.1016/j.ejcts.2006.03.011. Epub 2006 Mar 24. Eur J Cardiothorac Surg. 2006. PMID: 16563790 Review.
Cited by
-
[Antagonistic function of the heart muscle : Part II: Clinical implications].Herz. 2020 Apr;45(2):178-185. doi: 10.1007/s00059-018-4735-x. Epub 2018 Jul 27. Herz. 2020. PMID: 30054715 Review. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous