Experimental correlation-based identification of X-ray CT point spread function. Part 1: Method and experimental results
- PMID: 9136183
- DOI: 10.1007/BF02510384
Experimental correlation-based identification of X-ray CT point spread function. Part 1: Method and experimental results
Abstract
Knowledge of the point spread function (PSF) of an imaging system is important when studying the characteristics of the blur present in the images. Published experimental PSF identification techniques adapt classical one-dimensional linear system identification strategies using impulse, step function or periodic input signals. This study proposes and successfully applies a correlation method based on the Wiener-Hopf equation to identify the PSF of a CT scanner. The input consists of a series of pseudorandomly located holes. Results are found to be statistically equivalent to those obtained with the impulse method at a 90% two-sided confidence interval. Like the impulse method, it readily yields two-dimensional estimate, but the larger input circumvents the major objection to the use of a wire input. Furthermore, it is relatively immune to output noise, offering an advantage over edge methods. This resistance to noise may prove helpful for nuclear medicine imaging techniques, for which the signal-to-noise ratio is much lower than that X-ray for CT.
Similar articles
-
Experimental correlation-based identification of X-ray CT point spread function. Part 2: Simulation and design of input signal.Med Biol Eng Comput. 1997 Jan;35(1):9-16. doi: 10.1007/BF02510385. Med Biol Eng Comput. 1997. PMID: 9136184
-
Tilted-wire method for measuring resolution properties of CT images under extremely low-contrast and high-noise conditions.Radiol Phys Technol. 2018 Jun;11(2):125-137. doi: 10.1007/s12194-018-0443-8. Epub 2018 Feb 23. Radiol Phys Technol. 2018. PMID: 29476396
-
Performance measurement of PSF modeling reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT.Ann Nucl Med. 2014 May;28(4):340-8. doi: 10.1007/s12149-014-0815-z. Epub 2014 Feb 7. Ann Nucl Med. 2014. PMID: 24504938
-
Experimental evaluation of computerised tomography point spread function variability within the field of view: parametric models.Med Biol Eng Comput. 2004 Sep;42(5):591-7. doi: 10.1007/BF02347539. Med Biol Eng Comput. 2004. PMID: 15503958
-
Generation of realistic virtual nodules based on three-dimensional spatial resolution in lung computed tomography: A pilot phantom study.Med Phys. 2017 Oct;44(10):5303-5313. doi: 10.1002/mp.12503. Epub 2017 Aug 30. Med Phys. 2017. PMID: 28777462
Cited by
-
Identification of feedback loops embedded in cellular circuits by investigating non-causal impulse response components.J Math Biol. 2010 Feb;60(2):285-312. doi: 10.1007/s00285-009-0263-x. Epub 2009 Mar 31. J Math Biol. 2010. PMID: 19333603
-
Experimental correlation-based identification of X-ray CT point spread function. Part 2: Simulation and design of input signal.Med Biol Eng Comput. 1997 Jan;35(1):9-16. doi: 10.1007/BF02510385. Med Biol Eng Comput. 1997. PMID: 9136184