Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Apr;23(4):417-22.
doi: 10.1007/s001340050350.

Reliability of anion gap as an indicator of blood lactate in critically ill patients

Affiliations

Reliability of anion gap as an indicator of blood lactate in critically ill patients

J Levraut et al. Intensive Care Med. 1997 Apr.

Abstract

Objective: To evaluate the sensitivity, specificity, and predictive values of an elevated anion gap as an indicator of hyperlactatemia and to assess the contribution of blood lactate to the serum anion gap in critically ill patients.

Design: Prospective study.

Setting: General intensive care unit of a university hospital.

Patients: 498 patients, none with ketonuria, severe renal failure or aspirin, glycol, or methanol intoxication.

Measurements and results: The anion gap was calculated as [Na+]-[Cl-]-[TCO2]. Hyperlactatemia was defined as a blood lactate concentration above 2.5 mmol/l. The mean blood lactate concentration was 3.7 +/- 3.2 mmol/l and the mean serum anion gap was 14.3 +/- 4.2 mEq/l. The sensitivity of an elevated anion gap to reveal hyperlactatemia was only 44% [95% confidence interval (CI) 38 to 50], whereas specificity was 91% (CI 87 to 94 and the positive predictive value was 86% (CI 79 to 90). As expected, the poor sensitivity of the anion gap increased with the lactate threshold value, whereas the specificity decreased [for a blood lactate cut-off of 5 mmol/l: sensitivity = 67% (CI 58 to 75) and specificity = 83% (CI 79 to 87)]. The correlation between the serum anion gap and blood lactate was broad (r2 = 0.41, p < 0.001) and the slope of this relationship (0.48 +/- 0.026) was less than 1 (p < 0.001). The serum chloride concentration in patients with a normal anion gap (99.1 +/- 6.9 mmol/l) was comparable to that in patients with an elevated anion gap (98.8 +/- 7.1 mmol/l).

Conclusions: An elevated anion gap is not a sensitive indicator of moderate hyperlactatemia, but it is quite specific, provided the other main causes of the elevated anion gap have been eliminated. Changes in blood lactate only account for about half of the changes in anion gap, and serum chloride does not seem to be an important factor in the determination of the serum anion gap.

PubMed Disclaimer

LinkOut - more resources