Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 May;42(5):892-7.
doi: 10.1023/a:1018804128695.

Efficacy of electrical stimulation at frequencies higher than basal rate in canine stomach

Affiliations
Comparative Study

Efficacy of electrical stimulation at frequencies higher than basal rate in canine stomach

B O Familoni et al. Dig Dis Sci. 1997 May.

Abstract

The optimum frequency for electrically stimulating motility in the stomach is still in question. Some studies of gastric electrical stimulation (GES) at near physiologic frequencies have reported gastric electrical entrainment but with little efficacy in improving motility. In this study we examined the effectiveness of electrical stimulation at a broad range of frequencies in entraining gastric electrical activity (GEA) and eliciting contractions in a canine model. The stomachs of six dogs, each implanted with four pairs of stainless steel electrodes and two strain gauges were stimulated at frequencies ranging from 3 to 30 cycles/min. GEA and contractions were monitored before and during electrical stimulation. The ability of GES at different frequencies to reverse the effect of glucagon was also investigated. GEA was entrained in most animals at frequencies close to the intrinsic rate as well as at four to five times the intrinsic rate. At other stimulation frequencies, the recorded electrical control activity either remained unchanged, uncoupled, or became dysrhythmic. Contractile response to stimulation at four to five times the intrinsic rate were significantly higher than those at frequencies close to the intrinsic rate (P < 0.05). GES did not alter the effect of glucagon. Stimulation at a frequency of four times the basal rate of 5/min elicited the largest motility index in dogs. Stimulation at frequencies much higher than the physiologic rate warrants further study as a possible optimum range for GES.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Gastroenterology. 1987 Nov;93(5):958-65 - PubMed
    1. Gastroenterology. 1987 Jan;92(1):92-7 - PubMed
    1. Gastroenterology. 1980 Aug;79(2):311-4 - PubMed
    1. Am J Physiol. 1992 May;262(5 Pt 1):G826-34 - PubMed
    1. J Appl Physiol. 1972 Apr;32(4):567-70 - PubMed

Publication types

LinkOut - more resources