Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 Apr 15;30(2):72-84.
doi: 10.1002/(sici)1097-0320(19970415)30:2<72::aid-cyto2>3.0.co;2-f.

Toward a new reference method for the leukocyte five-part differential

Affiliations
Free article
Comparative Study

Toward a new reference method for the leukocyte five-part differential

W Hübl et al. Cytometry. .
Free article

Abstract

A flow cytometric method performing a five-part leukocyte differential based on three-color staining with anti-CD45-fluorescein isothiocyanate (FITC), anti-CD-14-phycoerythrin (PE)/Cy5, and a cocktail of PE-labeled anti-CD2, anti-CD16, and anti-HLA-DR antibodies was evaluated. Results obtained by using three different sample preparation procedures and two different flow cytometers were compared with those of a 1,000-cell manual differential for evaluation of accuracy. We observed excellent correlations with the manual differential for all leukocyte subclasses and even higher correlations between the different flow cytometric methods. Flow cytometric basophil results were identical to the manual counts, regardless of which sample preparation technique or flow cytometer was used. Therefore, we propose our flow cytometric method as the first acceptable automated reference method for basophil counting. The flow cytometric results for the other leukocyte subclasses were apparently influenced by the sample preparation, which could not be explained by cell loss during washing steps. Moreover, a small influence of the flow cytometer was also observed. Assessing the influence of sample storage, we found only minimal changes within 24 h. In establishing reference values, high precision of flow cytometric results facilitated detection of a significantly higher monocyte count for males (relative count: 7.08 +/- 1.73% vs. 6.44 +/- 1.33%, P < 0.05; absolute count: 0.536 +/- 0.181 x 10(9)/liter vs. 0.456 +/- 139 x 10(9)/liter, P < 0.01). Our data indicate that monoclonal antibody-based flow cytometry is a highly suitable reference method for the five-part differential: It also shows, however, that studies will have to put more emphasis on methodological issues to define a method that shows a high interlaboratory reproducibility.

PubMed Disclaimer

Publication types

LinkOut - more resources