Detection of human immunodeficiency virus type 1 (HIV-1) DNA and RNA sequences in HIV-1 antibody-positive blood donors in Uganda by the Roche AMPLICOR assay
- PMID: 9157145
- PMCID: PMC229693
- DOI: 10.1128/jcm.35.4.873-876.1997
Detection of human immunodeficiency virus type 1 (HIV-1) DNA and RNA sequences in HIV-1 antibody-positive blood donors in Uganda by the Roche AMPLICOR assay
Abstract
The ability of commercially available PCR-based assays to accurately detect or quantitate human immunodeficiency virus type 1 (HIV-1) DNA or RNA in individuals predominantly infected with HIV-1 subtypes A and D is not known. Therefore, peripheral leukocytes from 43 individuals in Kampala, Uganda, positive for HIV by the Western blot (immunoblot) assay were tested by using the Roche AMPLICOR HIV-1 assay for the detection of DNA gag sequences. Plasma from these same individuals was tested by using the Roche HIV-1 AMPLICOR MONITOR HIV-1 assay for the quantitation of HIV-1 RNA gag sequences. In addition, peripheral leukocytes were tested for HIV-1 DNA by using a lower annealing temperature or a different primer pair for the HIV-1 pol region. The proportions of individuals with detectable HIV-1 DNA and RNA gag sequences by the Roche assays were 74 and 90%, respectively. The proportions positive for HIV-1 DNA sequences by using a 50 degrees C annealing temperature or the pol primer pair were 71 and 98%, respectively. In summary, the standard Roche assay did not detect HIV-1 DNA sequences in a significant number of HIV-1-infected individuals in Uganda. However, use of a pol primer pair increased the sensitivity of the assay to 98%. The sensitivity of the Roche AMPLICOR MONITOR assay for the detection and quantitation of HIV-1 RNA sequences was significantly higher than that of the DNA-based assay, but the efficiency of the assay, and hence, the accuracy of the values obtained with RNA, is not known. Modifications to existing assays are needed to enhance the sensitivities and accuracies of these commercially available assays for use in developing countries where non-B HIV-1 subtypes predominate.
Similar articles
-
Evaluation of a prototype Amplicor PCR assay for detection of human immunodeficiency virus type 1 DNA in blood samples from Tanzanian adults infected with HIV-1 subtypes A, C and D.J Clin Virol. 2000 Jun;17(1):57-63. doi: 10.1016/s1386-6532(00)00073-1. J Clin Virol. 2000. PMID: 10814940
-
Comparison of NucliSens and Amplicor monitor assays for quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma of persons with HIV-1 subtype A infection in Abidjan, Côte d'Ivoire.J Clin Microbiol. 1998 Sep;36(9):2495-8. doi: 10.1128/JCM.36.9.2495-2498.1998. J Clin Microbiol. 1998. PMID: 9705381 Free PMC article.
-
Detection of southern African human immunodeficiency virus type 1 subtypes by polymerase chain reaction: evaluation of different primer pairs and conditions.J Virol Methods. 1995 Nov;55(3):391-400. doi: 10.1016/0166-0934(95)00088-7. J Virol Methods. 1995. PMID: 8609204
-
Quantification of HIV-1 group M (subtypes A-G) and group O by the LCx HIV RNA quantitative assay.J Virol Methods. 2000 Sep;89(1-2):97-108. doi: 10.1016/s0166-0934(00)00205-6. J Virol Methods. 2000. PMID: 10996643
-
Quantitation of HIV-1 RNA levels in plasma and CSF of asymptomatic HIV-1 infected patients from South India using a TaqMan real time PCR assay.J Clin Virol. 2007 May;39(1):9-15. doi: 10.1016/j.jcv.2006.12.026. Epub 2007 Mar 23. J Clin Virol. 2007. PMID: 17368087
Cited by
-
Determinations of levels of human immunodeficiency virus type 1 RNA in plasma: reassessment of parameters affecting assay outcome. TUBE Meeting Workshop Attendees. Technology Utilization for HIV-1 Blood Evaluation and Standardization in Pediatrics.J Clin Microbiol. 1998 Jun;36(6):1471-9. doi: 10.1128/JCM.36.6.1471-1479.1998. J Clin Microbiol. 1998. PMID: 9620364 Free PMC article. Review. No abstract available.
-
Performance of a multiplex qualitative PCR LCx assay for detection of human immunodeficiency virus type 1 (HIV-1) group M subtypes, group O, and HIV-2.J Clin Microbiol. 2000 Feb;38(2):716-23. doi: 10.1128/JCM.38.2.716-723.2000. J Clin Microbiol. 2000. PMID: 10655373 Free PMC article.
-
Comparative performance of three viral load assays on human immunodeficiency virus type 1 (HIV-1) isolates representing group M (subtypes A to G) and group O: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR version 1.5, and Quantiplex HIV-1 RNA version 3.0.J Clin Microbiol. 2001 Mar;39(3):862-70. doi: 10.1128/JCM.39.3.862-870.2001. J Clin Microbiol. 2001. PMID: 11230396 Free PMC article.
References
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources