Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 Jun;35(6):1385-9.
doi: 10.1128/jcm.35.6.1385-1389.1997.

Comparison of two automated DNA amplification systems with a manual one-tube nested PCR assay for diagnosis of pulmonary tuberculosis

Affiliations
Comparative Study

Comparison of two automated DNA amplification systems with a manual one-tube nested PCR assay for diagnosis of pulmonary tuberculosis

K Y Yuen et al. J Clin Microbiol. 1997 Jun.

Abstract

Eighty-four specimens of respiratory secretions culture positive for mycobacteria (70 positive for Mycobacterium tuberculosis and 14 positive for nontuberculous mycobacteria) and 120 culture-negative specimens were evaluated by three DNA amplification techniques: a manual in-house single-tube nested PCR (nPCR) and two commercial automated assays (the Cobas Amplicor System [aPCR-h] from Roche Diagnostic Systems and the Abbott LCx Probe System [aLCx-p] from Abbott Laboratories). The overall diagnostic sensitivities of the nPCR, aPCR-h, and aLCx-p were 77.1, 84.3, and 77.1%, respectively, and the sensitivities were 57.9, 57.9, and 36.8%, respectively, for smear-negative specimens. Specimens culture positive for nontuberculous mycobacteria were negative by all three assays. Eight culture-negative specimens which were positive by one or more assays had previously been documented by culture to be positive for M. tuberculosis and were taken from patients who were treated with antituberculosis agents. Retesting of specimens negative by one assay by the other two assays revealed that each test had its unique group of negative specimens. When considering the DNA extraction and amplification steps of these assays separately, it was found that extracts from aPCR-h and aLCx-p were compatible with nPCR amplication, while the two automated assays could only amplify extracts processed with their own reagents. Limiting dilution analysis revealed that the order of analytical sensitivity was nPCR, followed by aLCx-p and then aPCR-h. Comparison of the work flow of each assay revealed that although the aPCR-h demands the least specimen handling, the turnaround time of aLCx-p is the most favorable.

PubMed Disclaimer

References

    1. J Clin Microbiol. 1993 Jul;31(7):1688-94 - PubMed
    1. J Clin Microbiol. 1993 Aug;31(8):2049-56 - PubMed
    1. J Clin Microbiol. 1994 Feb;32(2):393-7 - PubMed
    1. J Clin Microbiol. 1994 Jun;32(6):1483-7 - PubMed
    1. J Clin Microbiol. 1996 Oct;34(10):2391-4 - PubMed

Publication types

MeSH terms

LinkOut - more resources