Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1997 May;21(5):359-64.
doi: 10.1016/s0143-4160(97)90029-4.

Time course of calcium transients derived from Fura-2 fluorescence measurements in single fast twitch fibres of adult mice and rat myotubes developing in primary culture

Affiliations
Comparative Study

Time course of calcium transients derived from Fura-2 fluorescence measurements in single fast twitch fibres of adult mice and rat myotubes developing in primary culture

A J Bakker et al. Cell Calcium. 1997 May.

Abstract

In this study, we applied a method to correct for the altered binding kinetics of Fura-2 for Ca2+ in vivo, on Ca2+ fluorescence transients (Ca2+F) measured using Fura-2 in single adult fast twitch skeletal muscle fibres of the mouse, which exhibit very fast [Ca2+] responses, and rat myotubes developing in culture which exhibit slower [Ca2+] responses (rise time [20-80% of peak] of Ca2+F transients: 1.81 +/- 0.17 ms and 16.14 +/- 2.60 ms, respectively). After correction, the [Ca2+] transients (Ca2+C) measured in both the adult mouse fibres and the myotubes rose more rapidly (mean rise time of Ca2+C transients: adult mouse fibres, 0.76 +/- 0.12 ms; rat myotubes, 8.25 +/- 2.83 ms) and often exhibited a Ca2+ spike which exceeded the peak of the Ca2+F transient. In the adult mouse fibres, correction increased the mean peak [Ca2+] of the Ca2+F transients by a factor of 7 from 0.53 +/- 0.08 microM to 3.76 +/- 0.71 microM. The accuracy of the time course of the corrected Ca2+ transients was confirmed by comparison to the time course of Ca2+ transients measured with Mag-Fura-5, which had a similar mean rise time (0.94 +/- 0.10 ms, t-test, P = 0.80). The more slowly rising Ca2+ transients measured in the rat myotubes were less affected by the correction process, increasing in mean peak [Ca2+] by a factor of only 1.2 from 0.82 +/- 0.17 microM to 0.97 +/- 0.15 microM. During the decay phase of the Ca2+ transients elicited in the adult mouse fibres and the myotubes, the corrected Ca2+C signal largely followed the unmodified Ca2+F transient. The correction process was found to have little effect on Ca2+ transients with rise time values greater than 10 ms, which included most of the Ca2+ transients measured in the myotubes.

PubMed Disclaimer

Publication types

LinkOut - more resources