Antimony in drinking water, red blood cells, and serum: development of analytical methodology using transversely heated graphite furnace atomization-atomic absorption spectrometry
- PMID: 9175512
- DOI: 10.1007/s002449900209
Antimony in drinking water, red blood cells, and serum: development of analytical methodology using transversely heated graphite furnace atomization-atomic absorption spectrometry
Abstract
An atomic absorption spectrometric (AAS) method has been developed for determining microg/L levels of Sb in samples of water and blood. The AAS method is based on the concept of stabilized temperature platform furnace atomization (STPF) realized through the use of a transversely heated graphite atomizer (THGA) furnace, longitudinal Zeeman-effect background correction, and matrix modification with palladium nitrate-magnesium nitrate-nitric acid. The method of standard additions is not mandatory. The detection limit (3 standard deviations of the blank) is 2.6 microg Sb/L for the water, red blood cells (RBCs), and serum samples. Data are presented on the degree of accuracy and precision. The THGA-AAS method is simple, fast, and contamination-free because the entire operation from sampling to AAS measurement is carried out in the same tube. The method has been applied to the determination of Sb in some leachate tap water samples derived from a static copper plumbing system containing Sn/Sb solders, and in small samples (0.5 ml) of RBCs and serum derived from rats given Sb-supplemented drinking water.
Similar articles
-
Influence of experimental parameters on the determination of antimony in seawater by atomic absorption spectrometry using a transversely heated graphite furnace with Zeeman-effect background correction.Anal Bioanal Chem. 2002 Dec;374(7-8):1282-9. doi: 10.1007/s00216-002-1606-2. Epub 2002 Oct 29. Anal Bioanal Chem. 2002. PMID: 12474098
-
[A Zeeman graphite furnace atomic absorption spectrometric method for the determination of trace copper and chromium in drinking water].Guang Pu Xue Yu Guang Pu Fen Xi. 1999 Aug;19(4):616-8. Guang Pu Xue Yu Guang Pu Fen Xi. 1999. PMID: 15818974 Chinese.
-
Aluminum determined in plasma and urine by atomic absorption spectroscopy with a transversely heated graphite atomizer furnace.Clin Chem. 1994 Mar;40(3):431-4. Clin Chem. 1994. PMID: 8131280
-
Determination of lead in blood by graphite furnace atomic absorption spectrometry--a critique.Sci Total Environ. 1989 Dec 15;89(3):237-50. doi: 10.1016/0048-9697(89)90263-5. Sci Total Environ. 1989. PMID: 2694372 Review.
-
[Atomization efficiency of graphite furnace in atomic absorption spectrometry].Guang Pu Xue Yu Guang Pu Fen Xi. 2002 Feb;22(1):135-8. Guang Pu Xue Yu Guang Pu Fen Xi. 2002. PMID: 12940051 Review. Chinese.
Cited by
-
Availability, Toxicology and Medical Significance of Antimony.Int J Environ Res Public Health. 2022 Apr 12;19(8):4669. doi: 10.3390/ijerph19084669. Int J Environ Res Public Health. 2022. PMID: 35457536 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous