Evaluation of the Critikon 8100 and Spacelabs 90207 non-invasive blood pressure monitors using a test simulator
- PMID: 9175568
- DOI: 10.1038/sj.jhh.1000416
Evaluation of the Critikon 8100 and Spacelabs 90207 non-invasive blood pressure monitors using a test simulator
Abstract
The Critikon Dinamap 8100 and the Spacelabs 90207 ambulatory non-invasive blood pressure (NIBP) monitors were evaluated using a test simulator using an evaluation protocol which covered a wide range of simulated pressures (with five determinations at each of six steps from 60/30 to 200/150 mm Hg), pulse rates (from 40 to 200 bpm), artefact levels (simulated motion and tremor artefact) and pulse strengths (down to 10% of the nominal strength). Determinations were made at 5 min intervals. The average and standard deviation of the five measurements at each condition were calculated. The Spacelabs recorded pressures with a greater consistency than the Dinamap which showed a higher standard deviation under all the conditions. The relatively high standard deviation of the recordings made by the Dinamap could explain the non-systematic errors found in some evaluations. Both instruments recorded pressures within 5 mm Hg of the target over the range of pressures and pulse rates, and coped well under conditions of severe artefact and weak pulsations, either by signalling inability to record or by recording satisfactorily.
Similar articles
-
Do SpaceLabs ambulatory non-invasive blood pressure recorders measure blood pressure consistently over several years use?Blood Press Monit. 2005 Feb;10(1):51-6. doi: 10.1097/00126097-200502000-00009. Blood Press Monit. 2005. PMID: 15687874
-
A simulation study of the consistency of oscillometric blood pressure measurements with and without artefacts.Blood Press Monit. 2000 Apr;5(2):69-79. Blood Press Monit. 2000. PMID: 10828893
-
A comparative evaluation of the DINAMAP 8100 and DINAMAP Compact TS using a non-invasive blood pressure simulator.Blood Press Monit. 1998 Oct;3(5):309-314. Blood Press Monit. 1998. PMID: 10212371
-
Survey of automated noninvasive blood pressure monitors.J Clin Eng. 1994 Nov-Dec;19(6):452-75. doi: 10.1097/00004669-199411000-00014. J Clin Eng. 1994. PMID: 10139740 Review.
-
Assessment of the validation of blood pressure monitors: a statistical reappraisal.Blood Press Monit. 2008 Aug;13(4):187-91. doi: 10.1097/MBP.0b013e3283071a64. Blood Press Monit. 2008. PMID: 18635972 Review.
Cited by
-
Nocturnal blood pressure non-dipping, posttraumatic stress disorder, and sleep quality in women.Behav Med. 2013;39(4):111-21. doi: 10.1080/08964289.2013.813434. Behav Med. 2013. PMID: 24236808 Free PMC article.
-
Ambulatory cardiovascular activity and hostility ratings in women with chronic posttraumatic stress disorder.Biol Psychiatry. 2009 Feb 1;65(3):268-72. doi: 10.1016/j.biopsych.2008.06.024. Epub 2008 Aug 9. Biol Psychiatry. 2009. PMID: 18692171 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical